Posture correction of dual-energy micro-CT system

In the dual-energy micro-CT system, the ideal posture relation is a necessary condition for high-quality imaging. However, existing posture calibration methods are not able to correct all the posture parameters of the dual-energy micro-CT system utilizing the optical coupler detector. To address this issue, we propose a posture correction method based on a single-sided nine-grids phantom. Scanning experiments and projection data reconstruction are conducted to validate the effectiveness of the proposed method. After posture correction, the absolute values of the coordinate offsets of dual-energy projection points in two directions are less than the unit pixel size of the detector. Besides, artifacts in the reconstruction images of both optical paths are reduced, leading to improved accuracy in material discrimination results from reconstruction images. The proposed method can correct all the posture parameters of the optical coupler detector, making it certainly practical for the micro-CT system utilizing the optical coupler detector.

Authors

Institutions

Publication Details

Journal
International Journal of Optomechatronics
Published
2024-10-11
DOI
https://doi.org/10.1080/15599612.2024.2409079
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Posture correction of dual-energy micro-CT system

Jing Zou, Jintao Zhao, Qi Zhang
International Journal of Optomechatronics
Advanced X-ray and CT Imaging
article

Posture correction of dual-energy micro-CT system

Jing Zou, Jintao Zhao, Qi Zhang
article en

Abstract

In the dual-energy micro-CT system, the ideal posture relation is a necessary condition for high-quality imaging. However, existing posture calibration methods are not able to correct all the posture parameters of the dual-energy micro-CT system utilizing the optical coupler detector. To address this issue, we propose a posture correction method based on a single-sided nine-grids phantom. Scanning experiments and projection data reconstruction are conducted to validate the effectiveness of the proposed method. After posture correction, the absolute values of the coordinate offsets of dual-energy projection points in two directions are less than the unit pixel size of the detector. Besides, artifacts in the reconstruction images of both optical paths are reduced, leading to improved accuracy in material discrimination results from reconstruction images. The proposed method can correct all the posture parameters of the optical coupler detector, making it certainly practical for the micro-CT system utilizing the optical coupler detector.

International Journal of OptomechatronicsVol. 18(1)
Tianjin University of Technology and Education (CN), Tianjin University (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Posture correction of dual-energy micro-CT system — Jing Zou, Jintao Zhao, et al. · International Journal of Optomechatronics (2024) | TGRS Research Map | TGRS