V-Spline Design for Enhanced Performance in Turbine Blade Internal Cooling

Abstract Past experiments have consistently shown that V-shaped rib turbulators are among the best in heat transfer performance. While there is literature on the V rib design in various experimental studies, there is no literature that shows the V rib design applied on any current turbine blades. Instead, the straight and angled rib design are used. The V rib only offers a marginally better heat transfer performance over the angled rib, but it has a severe stress concentration at the rib tip. In this research, multiple design augmentations were analyzed, with the addition of a spline at the center of the V exhibiting alleviation of the tip stress concentration. The results show that the presence of the spline not only resolves the fatigue issues but also increases the heat transfer performance by 4.3% and 8.2% against the V rib and angled rib design, respectively. With a better heat transfer performance, the creep analysis shows that the turbine blade with a V-spline rib design can operate at temperatures 203 °C hotter than an angled rib at the same fluid power. Given the dependence of engine thermal efficiency on turbine inlet temperature, this simple design shows good potential for heat transfer augmentation.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2024-10-11
DOI
https://doi.org/10.1115/1.4066828
Citations
2
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
2.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

V-Spline Design for Enhanced Performance in Turbine Blade Internal Cooling

Symus Yueyang Say, Adamya S. Dhaker, Wai Tuck Chow
2 citations
Journal of Engineering for Gas Turbines and Power
Turbomachinery Performance and Optimization
2.60
article

V-Spline Design for Enhanced Performance in Turbine Blade Internal Cooling

Symus Yueyang Say, Adamya S. Dhaker, Wai Tuck Chow
article en
2 citations

Abstract

Abstract Past experiments have consistently shown that V-shaped rib turbulators are among the best in heat transfer performance. While there is literature on the V rib design in various experimental studies, there is no literature that shows the V rib design applied on any current turbine blades. Instead, the straight and angled rib design are used. The V rib only offers a marginally better heat transfer performance over the angled rib, but it has a severe stress concentration at the rib tip. In this research, multiple design augmentations were analyzed, with the addition of a spline at the center of the V exhibiting alleviation of the tip stress concentration. The results show that the presence of the spline not only resolves the fatigue issues but also increases the heat transfer performance by 4.3% and 8.2% against the V rib and angled rib design, respectively. With a better heat transfer performance, the creep analysis shows that the turbine blade with a V-spline rib design can operate at temperatures 203 °C hotter than an angled rib at the same fluid power. Given the dependence of engine thermal efficiency on turbine inlet temperature, this simple design shows good potential for heat transfer augmentation.

Journal of Engineering for Gas Turbines and PowerVol. 147(6)
Nanyang Technological University (SG)
Openalex Percentile: Top 8%
Turbomachinery Performance and Optimization
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.