Thermal Exploration of Combined Rectangular and Semi-Circular Artificial Ribs in the Flow Regime of Solar Air Heater: A Computational and Experimental Approach

Abstract A roughened solar air heater is developed numerically and experimentally with a novel roughness in the absorber. The roughness incorporated is a combination of rectangular and semi-circular ribs. The analysis is done to improve the thermal characteristics considering two cases. Type A with ribs placed above the absorber and Type B with ribs placed below it. Several operating parameters are investigated including heat flux, Reynolds number (Re), relative obstacle relative height (h/H) ranging from 400 W/m2 to 1000 W/m2, 4000 to 10,000, and 0.4 to 1.0, respectively. The relative pitch is kept constant at 15 mm. The governing equations are simulated employing the renormalization group k–ε turbulence flow model. The results indicated that both Type A and Type B achieved significant improvements over the smooth duct. Type A exhibited a maximum Nusselt number of 4.24, while Type B achieved 3.93 in comparison with smooth duct at Re of 10,000, respectively. The thermal enhancement factor (TEF) ranges from 1.32 to 1.79 for Type A and 1.26 to 1.69 for Type B at a heat flux intensity of 1000 W/m2. Also at a relative height of 1.0, Type A demonstrated the highest TEF of 1.79 at Re = 10,000 and provided a maximum exergy efficiency of 11.2%.

Authors

Institutions

Publication Details

Journal
Journal of Solar Energy Engineering
Published
2024-10-11
DOI
https://doi.org/10.1115/1.4066843
Citations
8
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
1.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Exploration of Combined Rectangular and Semi-Circular Artificial Ribs in the Flow Regime of Solar Air Heater: A Computational and Experimental Approach

Biplab Das, Pranjal Prasad Newar
8 citations
Journal of Solar Energy Engineering
Heat Transfer Mechanisms
1.70
article

Thermal Exploration of Combined Rectangular and Semi-Circular Artificial Ribs in the Flow Regime of Solar Air Heater: A Computational and Experimental Approach

Biplab Das, Pranjal Prasad Newar
article en
8 citations

Abstract

Abstract A roughened solar air heater is developed numerically and experimentally with a novel roughness in the absorber. The roughness incorporated is a combination of rectangular and semi-circular ribs. The analysis is done to improve the thermal characteristics considering two cases. Type A with ribs placed above the absorber and Type B with ribs placed below it. Several operating parameters are investigated including heat flux, Reynolds number (Re), relative obstacle relative height (h/H) ranging from 400 W/m2 to 1000 W/m2, 4000 to 10,000, and 0.4 to 1.0, respectively. The relative pitch is kept constant at 15 mm. The governing equations are simulated employing the renormalization group k–ε turbulence flow model. The results indicated that both Type A and Type B achieved significant improvements over the smooth duct. Type A exhibited a maximum Nusselt number of 4.24, while Type B achieved 3.93 in comparison with smooth duct at Re of 10,000, respectively. The thermal enhancement factor (TEF) ranges from 1.32 to 1.79 for Type A and 1.26 to 1.69 for Type B at a heat flux intensity of 1000 W/m2. Also at a relative height of 1.0, Type A demonstrated the highest TEF of 1.79 at Re = 10,000 and provided a maximum exergy efficiency of 11.2%.

Journal of Solar Energy EngineeringVol. 147(3)
National Institute Of Technology Silchar (IN)
Openalex Percentile: Top 17%
Heat Transfer Mechanisms
1.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.