ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System

High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix α-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2024-10-11
DOI
https://doi.org/10.1021/jasms.4c00340
Citations
2
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System

Thorsten Adolphs, Richard E. Peterson, Bonnie J. Tyler, Florian Boße et al.
2 citations
Journal of the American Society for Mass Spectrometry
Ion-surface interactions and analysis
0.75
article

ToF-SIMS Investigation of Environmental Effects on Analyte Migration in Matrix Coatings for Mass Spectrometry Imaging Using a Newly Developed Vapor Deposition System

Thorsten Adolphs, Richard E. Peterson, Bonnie J. Tyler, Florian Boße, Bart Jan Ravoo, Heinrich F. Arlinghaus, Michael Bäumer
article en
2 citations

Abstract

High resolution mass spectrometry images are of increasing importance in biological applications, such as the study of tissues and single cells. Two promising techniques for this are matrix-enhanced secondary ion mass spectrometry (ME-SIMS) and matrix-assisted laser desorption/ionization (MALDI). For both techniques, the sample of interest must be coated with a matrix prior to analysis, and analytes must migrate into the matrix. The mechanisms involved in this migration and the factors that influence the migration are poorly understood, which lead to difficulties with reproducibility. In this work, a sublimation matrix coater with an effusion cell and sample cooling was developed and built in-house for controlled physical vapor deposition. In this system, sample transfer between the coater and mass spectrometer is possible without breaking vacuum, which facilitates the study of environmental influences on analyte migration. The influence of exposure to ambient air on the migration of two analytes (a lipid and a peptide), which were coated with the matrix α-cyano-4-hydroxycinnamic acid (CHCA), was studied using 3D-SIMS imaging. Although the distribution of analyte in the matrix changed very little after 21 h of storage in vacuum, significant redistribution of the analyte was observed after exposure to ambient air. The magnitude of the effect was greater for the lipid than for the peptide. Further work is needed to determine the role of humidity in the redistribution process and the impact of analyte redistribution on MALDI measurements.

Journal of the American Society for Mass SpectrometryVol. 35(12)
University of Münster (DE)
Climate action
Openalex Percentile: Top 32%
Ion-surface interactions and analysis
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.