Noise Reduction of Amperometric Electrochemical Sensor using Current Compensation on Transimpedance Amplifier for Dissolved Oxygen Measurement

In this paper, a study of noise reduction of an electrochemical sensor is presented. This study is initiated based on the fact that the signal from the electrochemical sensor has quite high noise. The current signal from the sensor is very weak and noisy due to high impedance and complex process on the sensor and measured media such as a solution of dissolved oxygen. The current is usually converted using a transimpedance amplifier with high voltage-to-current ratio by a feedback resistance, which usually also produces large noise due to high feedback resistance value. This will contribute to an additional noise to the natural noise of the sensor and measured media, causing more noisy result. A modified transimpedance amplifier is proposed to reduce the noise from the sensor and converter to increase signal-to-noise ratio. The modification employs a current compensation, so that the current noise is suppressed at the converter input. The noise and signal measurements at the output of the compensated transimpedance amplifier show noise reduction compared to the standard transimpedance amplifier and measurement error reduction of the measured dissolved oxygen down to 0.89%.

Authors

Institutions

Publication Details

Journal
Fluctuation and Noise Letters
Published
2024-10-11
DOI
https://doi.org/10.1142/s0219477525500154
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noise Reduction of Amperometric Electrochemical Sensor using Current Compensation on Transimpedance Amplifier for Dissolved Oxygen Measurement

Lazuardi Umar, Rahmondia Nanda Setiadi, Arfianti Arfianti
2 citations
Fluctuation and Noise Letters
Analytical Chemistry and Sensors
0.58
article

Noise Reduction of Amperometric Electrochemical Sensor using Current Compensation on Transimpedance Amplifier for Dissolved Oxygen Measurement

Lazuardi Umar, Rahmondia Nanda Setiadi, Arfianti Arfianti
article en
2 citations

Abstract

In this paper, a study of noise reduction of an electrochemical sensor is presented. This study is initiated based on the fact that the signal from the electrochemical sensor has quite high noise. The current signal from the sensor is very weak and noisy due to high impedance and complex process on the sensor and measured media such as a solution of dissolved oxygen. The current is usually converted using a transimpedance amplifier with high voltage-to-current ratio by a feedback resistance, which usually also produces large noise due to high feedback resistance value. This will contribute to an additional noise to the natural noise of the sensor and measured media, causing more noisy result. A modified transimpedance amplifier is proposed to reduce the noise from the sensor and converter to increase signal-to-noise ratio. The modification employs a current compensation, so that the current noise is suppressed at the converter input. The noise and signal measurements at the output of the compensated transimpedance amplifier show noise reduction compared to the standard transimpedance amplifier and measurement error reduction of the measured dissolved oxygen down to 0.89%.

Fluctuation and Noise LettersVol. 24(02)
Riau University (ID)
Kementerian Pendidikan, Kebudayaan, Riset, dan Teknologi
Clean water and sanitation
Openalex Percentile: Top 37%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Noise Reduction of Amperometric Electrochemical Sensor using Current Compensation on Transimpedance Amplifier for Dissolved Oxygen Measurement — Lazuardi Umar, Rahmondia Nanda Setiadi, et al. · Fluctuation and Noise Letters (2024) | TGRS Research Map | TGRS