Experimental Evaluation of a New Perfusion Machine Using Normothermic Cycles on Explanted Livers
<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Goal:</i> Organ perfusion is a vast subject with several techniques, the most common being Hypothermic Machine Perfusion (HMP) and Normothermic Machine Perfusion (NMP). In this paper, a new machine developed at the Biolab of the University of Florence has been tested to validate its capability to perform a well-controlled Oxygenated Rewarming (COR) phase and maintain stability during the NMP phase. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</i> The tests (n = 5) were conducted on fresh porcine livers and evaluated according to liver perfusion standards. The developed machine is based on a previous version, with an integrated control and sensor system and a complete mechanical and electronic redesign. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Results:</i> The results demonstrate the excellent usability of the machine and its ability to effectively maintain the organs in good condition. The new system performed well, and the measures made on the livers were satisfactory for good preservation of the organ. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Conclusion:</i> This study showed the effectiveness of the developed machine. Future development of the system will include a more sophisticated control system to ensure the correct parameters for perfusion.
Authors
- Gian Luca Grazi (ORCID: https://orcid.org/0000-0002-3279-0313)
- Leonardo Bocchi (ORCID: https://orcid.org/0000-0001-5109-3399)
- Matteo Risaliti (ORCID: https://orcid.org/0000-0001-8476-2536)
- Rebecca Panconesi (ORCID: https://orcid.org/0000-0003-2708-1261)
- Nadia Navari (ORCID: https://orcid.org/0000-0003-0371-7990)
- Mauricio Flores Carvalho (ORCID: https://orcid.org/0000-0001-6860-5733)
- Cosimo Nardi (ORCID: https://orcid.org/0000-0002-5489-7824)
- Fabio Staderini (ORCID: https://orcid.org/0000-0002-2438-2563)
- Andrea Schlegel (ORCID: https://orcid.org/0000-0002-9385-9847)
- Andrea Corvi (ORCID: https://orcid.org/0000-0002-6714-1110)
- Lorenzo Maggi (ORCID: https://orcid.org/0000-0002-6327-1495)
- Eleonora Barcali (ORCID: https://orcid.org/0000-0001-8924-1377)
- Fabio Marra (ORCID: https://orcid.org/0000-0001-8629-0878)
- Philipp Dutkowski (ORCID: https://orcid.org/0000-0002-3016-604X)
- Mattia Dimitri (ORCID: https://orcid.org/0000-0001-9719-9498)
- Adriano Peris (ORCID: https://orcid.org/0000-0002-9729-2331)
- Filippo Bigi
Institutions
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
- European Society for Sexual Medicine (IT)
- University Hospital of Zurich (CH)
- University of Florence (IT)
Publication Details
- Journal
- IEEE Open Journal of Engineering in Medicine and Biology
- Published
- 2024-10-11
- DOI
- https://doi.org/10.1109/ojemb.2024.3478791
- Primary Topic
- Ultrasound and Cavitation Phenomena
- Type
- article
- Field-Weighted Citation Impact
- 0.00