New approach for accurate discrimination and location of power transformers with different internal winding faults

Power transformers are essential elements in power systems and thus their protection schemes have critical importance. In this paper, a scheme is proposed for accurate discrimination and location of internal faults in power transformers using conventional measuring devices attached to the transformer. Different types of internal winding faults are intensely considered: partial discharge, inter-disk faults, series and shunt short circuit faults and axial displacement. Depending on the transformer measured output voltage, input voltage and the input current, the construction of a locus diagram (ΔV-Iin) serves as an indicator for any physical modification to the winding. Using five suggested features extracted from the developed locus, an artificial neural network (ANN) technique is applied to accurately distinguish any deviation from the transformer healthy condition. The exact location of each fault inside the windings of power transformer is then determined. The obtained results validate the usefulness of the proposed scheme for different internal faults. The superiority of the proposed scheme is extensively examined by comparing its results with some published schemes.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-10-11
DOI
https://doi.org/10.1371/journal.pone.0309926
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New approach for accurate discrimination and location of power transformers with different internal winding faults

M. Youssef, Mohammed El Hadi Attia, El-Said Abdelaziz, Hassan Saad
PLoS ONE
Power Transformer Diagnostics and Insulation
article

New approach for accurate discrimination and location of power transformers with different internal winding faults

M. Youssef, Mohammed El Hadi Attia, El-Said Abdelaziz, Hassan Saad
article en

Abstract

Power transformers are essential elements in power systems and thus their protection schemes have critical importance. In this paper, a scheme is proposed for accurate discrimination and location of internal faults in power transformers using conventional measuring devices attached to the transformer. Different types of internal winding faults are intensely considered: partial discharge, inter-disk faults, series and shunt short circuit faults and axial displacement. Depending on the transformer measured output voltage, input voltage and the input current, the construction of a locus diagram (ΔV-Iin) serves as an indicator for any physical modification to the winding. Using five suggested features extracted from the developed locus, an artificial neural network (ANN) technique is applied to accurately distinguish any deviation from the transformer healthy condition. The exact location of each fault inside the windings of power transformer is then determined. The obtained results validate the usefulness of the proposed scheme for different internal faults. The superiority of the proposed scheme is extensively examined by comparing its results with some published schemes.

PLoS ONEVol. 19(10)
Al-Azhar University (EG), El Shorouk Academy (EG), Higher Institute of Engineering (EG)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 85%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.