Measurement of response characteristics of photodetectors with low divergence angle dependence

A low divergence angle dependent trap photodetector was designed based on two photodiodes and a concave mirror, which can adapt to measurement of both spatially collimated beam and divergent beam in a small space. To determine responsivity of the trap detector, cryogenic radiometer system is used to calibrate trap detector under the condition of collimated beam, while the angular dependence can be ignored at a certain uncertainty level. Responsivity of trap detectors based on silicon photodiodes are calibrated traceable to cryogenic radiometer, with an uncertainty of less than 0.1%. The uniformity of photodetector is measured to be about 0.03% in a 5mm×5mm sensitive area and angular dependence is less than 0.1% when the angle between the incident beam axis and the normal direction of the detector surface is less than 7 degrees. The results show that the detector with this structure has a good consistency in the response of measuring collimated light beam and divergent light beam within a certain divergence angle.

Authors

Publication Details

Published
2024-10-11
DOI
https://doi.org/10.1117/12.3035878
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of response characteristics of photodetectors with low divergence angle dependence

Yandong Lin, Xiangliang Liu, Nan Xu, Zhiwei Liu et al.
Advanced Optical Sensing Technologies
article

Measurement of response characteristics of photodetectors with low divergence angle dependence

Yandong Lin, Xiangliang Liu, Nan Xu, Zhiwei Liu, Ruoduan Sun, QiMing Fan
article en

Abstract

A low divergence angle dependent trap photodetector was designed based on two photodiodes and a concave mirror, which can adapt to measurement of both spatially collimated beam and divergent beam in a small space. To determine responsivity of the trap detector, cryogenic radiometer system is used to calibrate trap detector under the condition of collimated beam, while the angular dependence can be ignored at a certain uncertainty level. Responsivity of trap detectors based on silicon photodiodes are calibrated traceable to cryogenic radiometer, with an uncertainty of less than 0.1%. The uniformity of photodetector is measured to be about 0.03% in a 5mm×5mm sensitive area and angular dependence is less than 0.1% when the angle between the incident beam axis and the normal direction of the detector surface is less than 7 degrees. The results show that the detector with this structure has a good consistency in the response of measuring collimated light beam and divergent light beam within a certain divergence angle.

Openalex Percentile: Top 85%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.