Corneal elasticity measurement by compressive optical coherence elastography system

Optical Coherence Elastography (OCE) is a non-invasive elastography technique, which can deduce the elastic properties of tissue by measuring the displacement or deformation in tissue caused by internal or external excitation. In recent years, it has been well accepted that the biomechanical properties of cornea are associated with various ophthalmic diseases. OCE has exhibited a good potential in measuring corneal elasticity, and however in vivo quantitative measurement remains challenging. Thus, in this paper, we designed an OCE system equipped with a load-measuring stress sensor to measure the deformation and geometric parameters of cornea during compression. Furthermore, a compressive OCE corneal elasticity measurement model was developed based on shell theory, which is dedicated to translating the measured value into Young's modulus. Finally, the method was evaluated on both artificial eye model and porcine cornea ex vivo. The results indicate that the OCE measurement combined with shell model can potentially aid in clinical measurement on cornea elasticity in vivo.

Authors

Institutions

Publication Details

Published
2024-10-11
DOI
https://doi.org/10.1117/12.3033492
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corneal elasticity measurement by compressive optical coherence elastography system

Yunfeng Mo, Ziye Chen, Zhilong Yan, Xinyuan Cao et al.
Corneal surgery and disorders
article

Corneal elasticity measurement by compressive optical coherence elastography system

Yunfeng Mo, Ziye Chen, Zhilong Yan, Xinyuan Cao, Jianhua Mo, Jie Lv, Qijie Wu
article en

Abstract

Optical Coherence Elastography (OCE) is a non-invasive elastography technique, which can deduce the elastic properties of tissue by measuring the displacement or deformation in tissue caused by internal or external excitation. In recent years, it has been well accepted that the biomechanical properties of cornea are associated with various ophthalmic diseases. OCE has exhibited a good potential in measuring corneal elasticity, and however in vivo quantitative measurement remains challenging. Thus, in this paper, we designed an OCE system equipped with a load-measuring stress sensor to measure the deformation and geometric parameters of cornea during compression. Furthermore, a compressive OCE corneal elasticity measurement model was developed based on shell theory, which is dedicated to translating the measured value into Young's modulus. Finally, the method was evaluated on both artificial eye model and porcine cornea ex vivo. The results indicate that the OCE measurement combined with shell model can potentially aid in clinical measurement on cornea elasticity in vivo.

Soochow University (CN)
Affordable and clean energy
Openalex Percentile: Top 70%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.