Pupil segmentation beam collimation method

In this paper, an approach for beam collimation by pupil segmentation is proposed. In this approach, the divergent or convergent wavefront of the beam to be collimated is divided into a series of subwavefronts by a microlens array, and the beam collimation is realized by comparing the difference of centroids between the actual spots and the reference ones under the paraxial approximation. In the experiment, the size of the beam to be collimated is limited by a stop aperture to satisfy the paraxial approximation. Using the proposed method, a divergent beam is collimated by a doublet with a focal length of 100 mm under the paraxial approximation. The test results of the collimated beam by a Shack-Hartmann sensor show that the root mean square of the wavefront of the collimated beam is 0.02 λ, having a good agreement with results of the proposed method. The experimental results show that the method is simple, low cost and highly accurate.

Authors

Publication Details

Published
2024-10-11
DOI
https://doi.org/10.1117/12.3030905
Primary Topic
Nail Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pupil segmentation beam collimation method

Changwei Li, Zijin Deng
Nail Diseases and Treatments
article

Pupil segmentation beam collimation method

Changwei Li, Zijin Deng
article en

Abstract

In this paper, an approach for beam collimation by pupil segmentation is proposed. In this approach, the divergent or convergent wavefront of the beam to be collimated is divided into a series of subwavefronts by a microlens array, and the beam collimation is realized by comparing the difference of centroids between the actual spots and the reference ones under the paraxial approximation. In the experiment, the size of the beam to be collimated is limited by a stop aperture to satisfy the paraxial approximation. Using the proposed method, a divergent beam is collimated by a doublet with a focal length of 100 mm under the paraxial approximation. The test results of the collimated beam by a Shack-Hartmann sensor show that the root mean square of the wavefront of the collimated beam is 0.02 λ, having a good agreement with results of the proposed method. The experimental results show that the method is simple, low cost and highly accurate.

Openalex Percentile: Top 73%
Nail Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.