Characterisation and modification of the porous metal foams used for the EN 15051-2 dustiness rotating drum test

Two approaches were used to evaluate the performance of the reticulated metal foams used to size select and collect dust generated in the dustiness rotating drum tester according to the EN 15051-2 standard "Workplace exposure-Measurement of the dustiness of bulk materials-Rotating drum test". Firstly, the detailed performance of the metal foams was measured in a calm air chamber using a polydisperse aerosol of glass particles and assessed against the respirable conventions described in the EN 481 standard "Workplace atmospheres-Size fraction definitions for measurement of airborne particles". Secondly, the performance of the EN 15051-2 metal foam size selection for the respirable fraction was compared using the rotating drum dustiness test, with that of a cyclone set-up, using 4 polydisperse glass powders of different size distribution and dustiness potential. The research discusses further improvements to the EN 15051-2 standard and an approach to more closely match the EN 481 convention. In general, for the respirable fraction, the tests in this study demonstrated a conservative oversampling by the current EN 15051-2 metal foam set-up in comparison with the EN 481 convention. Calculations and tests showed an improved fit was achieved by reducing the inner diameter of the flanges separating the metal foams and the filter. This study also showed the importance of sealing the circumference of the metal foams when testing highly dusty powders. A direct comparison of the respirable dustiness fraction, measured by the current EN 15051-2 metal foams set-up and by a cyclone set-up, showed broad agreement. However, for extremely dusty powders, the metal foams can clog, and dust can accumulate between the 20 and 80 pores per inch foams.

Authors

Institutions

Publication Details

Journal
Annals of Work Exposures and Health
Published
2024-10-11
DOI
https://doi.org/10.1093/annweh/wxae076
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterisation and modification of the porous metal foams used for the EN 15051-2 dustiness rotating drum test

Kirsty Dewberry, A. Thorpe, M.A. Hemingway, Delphine Bard et al.
Annals of Work Exposures and Health
Aerosol Filtration and Electrostatic Precipitation
article

Characterisation and modification of the porous metal foams used for the EN 15051-2 dustiness rotating drum test

Kirsty Dewberry, A. Thorpe, M.A. Hemingway, Delphine Bard, Graeme Hunwin, Garry Burdett
article en

Abstract

Two approaches were used to evaluate the performance of the reticulated metal foams used to size select and collect dust generated in the dustiness rotating drum tester according to the EN 15051-2 standard "Workplace exposure-Measurement of the dustiness of bulk materials-Rotating drum test". Firstly, the detailed performance of the metal foams was measured in a calm air chamber using a polydisperse aerosol of glass particles and assessed against the respirable conventions described in the EN 481 standard "Workplace atmospheres-Size fraction definitions for measurement of airborne particles". Secondly, the performance of the EN 15051-2 metal foam size selection for the respirable fraction was compared using the rotating drum dustiness test, with that of a cyclone set-up, using 4 polydisperse glass powders of different size distribution and dustiness potential. The research discusses further improvements to the EN 15051-2 standard and an approach to more closely match the EN 481 convention. In general, for the respirable fraction, the tests in this study demonstrated a conservative oversampling by the current EN 15051-2 metal foam set-up in comparison with the EN 481 convention. Calculations and tests showed an improved fit was achieved by reducing the inner diameter of the flanges separating the metal foams and the filter. This study also showed the importance of sealing the circumference of the metal foams when testing highly dusty powders. A direct comparison of the respirable dustiness fraction, measured by the current EN 15051-2 metal foams set-up and by a cyclone set-up, showed broad agreement. However, for extremely dusty powders, the metal foams can clog, and dust can accumulate between the 20 and 80 pores per inch foams.

Annals of Work Exposures and HealthVol. 69(1)
HSE Science and Research Centre (GB)
Health and Safety Executive
Sustainable cities and communities
Openalex Percentile: Top 85%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.