Enhancing Complementary Split Ring Resonators Performance for Atherosclerosis Diagnosis

This paper presents an improved complementary split ring resonator (CSRR) used as a non-invasive microwave sensor for in-vivo detection of atherosclerotic plaques. The sensor geometry was optimized on low-loss substrates to enhance the trade-off between the energy stored in the resonator and the energy radiated into the biological tissue. For positioning on the patient’s neck, the sensors were simulated in the presence of multilayer structures, and animal tissue samples were used for validation to estimate the penetration depth of the electromagnetic waves in these tissues. Finally, a three-dimensional model of the carotid artery was developed to extend the analysis beyond the tissues of the neck. The simulated results offer promising prospects for in-vivo diagnosis of carotid atherosclerotic plaques using these optimized CSRRs.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798279
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Complementary Split Ring Resonators Performance for Atherosclerosis Diagnosis

Hamid Kokabi, Joséphine Masini, Dimitri Galayko, O. Meyer et al.
1 citations
ECG Monitoring and Analysis
0.40
article

Enhancing Complementary Split Ring Resonators Performance for Atherosclerosis Diagnosis

Hamid Kokabi, Joséphine Masini, Dimitri Galayko, O. Meyer, Frédérique Deshours, Jean‐Michel Davaine, Sylvain Feruglio, G. Alquié
article en
1 citations

Abstract

This paper presents an improved complementary split ring resonator (CSRR) used as a non-invasive microwave sensor for in-vivo detection of atherosclerotic plaques. The sensor geometry was optimized on low-loss substrates to enhance the trade-off between the energy stored in the resonator and the energy radiated into the biological tissue. For positioning on the patient’s neck, the sensors were simulated in the presence of multilayer structures, and animal tissue samples were used for validation to estimate the penetration depth of the electromagnetic waves in these tissues. Finally, a three-dimensional model of the carotid artery was developed to extend the analysis beyond the tissues of the neck. The simulated results offer promising prospects for in-vivo diagnosis of carotid atherosclerotic plaques using these optimized CSRRs.

Centre National de la Recherche Scientifique (FR), Laboratoire de Génie Électrique et Électronique de Paris (FR), Sorbonne Université (FR), Assistance Publique – Hôpitaux de Paris (FR), Pitié-Salpêtrière Hospital (FR), Institut d'Électronique et des Systèmes (FR), LIP6 (FR)
Openalex Percentile: Top 32%
ECG Monitoring and Analysis
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.