Subnormothermic Oxygenated Machine Perfusion (24 h) in DCD Kidney Transplantation

Background: Ex vivo kidney perfusion is an evolving platform that demonstrates promise in preserving and rehabilitating the kidney grafts. Despite this, there is little consensus on the optimal perfusion conditions. Hypothermic perfusion offers limited functional assessment, whereas normothermic perfusion requires a more complex mechanical system and perfusate. Subnormothermic machine perfusion (SNMP) has the potential to combine the advantages of both approaches but has undergone limited investigation. Therefore, the present study sought to determine the suitability of SNMP for extended kidney preservation. Methods: SNMP at 22-25 °C was performed on a portable device for 24 h with porcine kidneys. Graft assessment included measurement of mechanical parameters and biochemical analysis of the perfusate using point-of-care tests. To investigate the viability of kidneys preserved by SNMP, porcine kidney autotransplants were performed in a donation after circulatory death (DCD) model. SNMP was also compared with static cold storage (SCS). Finally, follow-up experiments were conducted in a subset of human kidneys to test the translational significance of findings in porcine kidneys. Results: In the perfusion-only cohort, porcine kidneys all displayed successful perfusion for 24 h by SNMP, evidenced by stable mechanical parameters and biological markers of graft function. Furthermore, in the transplant cohort, DCD grafts with 30 min of warm ischemic injury demonstrated superior posttransplant graft function when preserved by SNMP in comparison with SCS. Finally, human kidneys that underwent 24-h perfusion exhibited stable functional and biological parameters consistent with observations in porcine organs. Conclusions: These observations demonstrate the suitability and cross-species generalizability of subnormothermic machine perfusion to maintain stable kidney perfusion and provide foundational evidence for improved posttransplant graft function of DCD kidneys after SNMP compared with SCS.

Authors

Institutions

Publication Details

Journal
UNC Libraries
Published
2024-10-11
DOI
https://doi.org/10.17615/hja7-hc39
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Subnormothermic Oxygenated Machine Perfusion (24 h) in DCD Kidney Transplantation

Qimeng Gao, David N. Howell, Ryan Neill, Charles Aardema et al.
UNC Libraries
Renal Transplantation Outcomes and Treatments
article

Subnormothermic Oxygenated Machine Perfusion (24 h) in DCD Kidney Transplantation

Qimeng Gao, David N. Howell, Ryan Neill, Charles Aardema, Nader Abraham, Andrew S. Barbas, Bangchen Wang, Joseph M. Ladowski, Imran J. Anwar, Kentaro Nakata, Matthew Galen Hartwig, Riley Kahan, Prabir Roy‐Chaudhury, David A. Gerber, Benjamin A. Hughes, Greta Cywińska, Kendall Hlewicki, Isaac S. Alderete, E. Jarrett
article en

Abstract

Background: Ex vivo kidney perfusion is an evolving platform that demonstrates promise in preserving and rehabilitating the kidney grafts. Despite this, there is little consensus on the optimal perfusion conditions. Hypothermic perfusion offers limited functional assessment, whereas normothermic perfusion requires a more complex mechanical system and perfusate. Subnormothermic machine perfusion (SNMP) has the potential to combine the advantages of both approaches but has undergone limited investigation. Therefore, the present study sought to determine the suitability of SNMP for extended kidney preservation. Methods: SNMP at 22-25 °C was performed on a portable device for 24 h with porcine kidneys. Graft assessment included measurement of mechanical parameters and biochemical analysis of the perfusate using point-of-care tests. To investigate the viability of kidneys preserved by SNMP, porcine kidney autotransplants were performed in a donation after circulatory death (DCD) model. SNMP was also compared with static cold storage (SCS). Finally, follow-up experiments were conducted in a subset of human kidneys to test the translational significance of findings in porcine kidneys. Results: In the perfusion-only cohort, porcine kidneys all displayed successful perfusion for 24 h by SNMP, evidenced by stable mechanical parameters and biological markers of graft function. Furthermore, in the transplant cohort, DCD grafts with 30 min of warm ischemic injury demonstrated superior posttransplant graft function when preserved by SNMP in comparison with SCS. Finally, human kidneys that underwent 24-h perfusion exhibited stable functional and biological parameters consistent with observations in porcine organs. Conclusions: These observations demonstrate the suitability and cross-species generalizability of subnormothermic machine perfusion to maintain stable kidney perfusion and provide foundational evidence for improved posttransplant graft function of DCD kidneys after SNMP compared with SCS.

UNC Libraries
University of North Carolina at Chapel Hill (US)
Openalex Percentile: Top 67%
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.