Analytical Method for the Development and Validation of Residual Solvents in Tigecycline by Gas Chromatography Using Headspace Sampling Technology

Residual solvents such as Dichloromethane, Acetone, Methanol, and Isopropanol in pharmaceutical samples of Tigecycline were monitored using gas chromatography with headspace sampling technology. The column used for this elution is DB-624, 30m X 0.32mm X 1.8µm, Nitrogen is used as carrier gas with FID detector. Split ratio is 30:1 and the injector temperature is 210 °C. Estimation of the residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). So, in this study, the authors estimated the four residual solvents of Tigecycline using the Headspace sampling technology, and the method is validated and meets all required standards per the ICH revised guidelines. So, this method can be used for routine analysis in Quality control laboratories for routine estimation.

Authors

Institutions

Publication Details

Journal
Biosciences Biotechnology Research Asia
Published
2024-09-30
DOI
https://doi.org/10.13005/bbra/3280
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method for the Development and Validation of Residual Solvents in Tigecycline by Gas Chromatography Using Headspace Sampling Technology

Mohammed Abdul Farhan, Anupama Koneru, M. Mushraff Ali Khan, Shaik Liyaqat et al.
Biosciences Biotechnology Research Asia
Analytical Chemistry and Chromatography
article

Analytical Method for the Development and Validation of Residual Solvents in Tigecycline by Gas Chromatography Using Headspace Sampling Technology

Mohammed Abdul Farhan, Anupama Koneru, M. Mushraff Ali Khan, Shaik Liyaqat, Syed Imam Pasha
article en

Abstract

Residual solvents such as Dichloromethane, Acetone, Methanol, and Isopropanol in pharmaceutical samples of Tigecycline were monitored using gas chromatography with headspace sampling technology. The column used for this elution is DB-624, 30m X 0.32mm X 1.8µm, Nitrogen is used as carrier gas with FID detector. Split ratio is 30:1 and the injector temperature is 210 °C. Estimation of the residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). So, in this study, the authors estimated the four residual solvents of Tigecycline using the Headspace sampling technology, and the method is validated and meets all required standards per the ICH revised guidelines. So, this method can be used for routine analysis in Quality control laboratories for routine estimation.

Biosciences Biotechnology Research AsiaVol. 21(3)
CARE Hospitals (IN)
Openalex Percentile: Top 87%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.