A unified calibration method for robot manipulators: hand-eye parameters, kinematic parameters and TCP position calibration

Purpose The purpose of the paper is to propose an efficient, simple and concise unified robot calibration method that simultaneously considers errors in hand-eye parameters, kinematic parameters and tool center point (TCP) position. Design/methodology/approach This paper proposes a unified robot calibration method. First, the initial hand-eye matrix and TCP position are computed without considering kinematic parameter errors. Second, the nominal TCP positions in the laser tracker coordinate system {S} are computed. The actual TCP positions in {S} are directly measured. Third, a unified parameter error calibration model is established, and the sequential quadratic programming algorithm is used for error identification. Finally, the identified errors are used for direct error compensation. Findings Simulation results prove that the proposed scheme can accurately calibrate the hand-eye parameters, kinematic parameters and TCP position simultaneously. Experimental results reveal that the maximum value of the absolute positioning errors is reduced from 5.4725 mm to 0.4095 mm (reduced by 92.52%). Thus, the proposed approach meets the accuracy requirements of most robotic applications. Originality/value The main contributions of this paper are: (1) this scheme is efficient. The method can achieve fully automatic calibration by incorporating Kronecker products for the initial hand-eye matrix and TCP position computation. Thereby significantly improving the calibration efficiency and liberating the labor force. (2) This scheme is simple and concise. The hand-eye parameters, kinematic parameters and TCP position errors are modeled in a unified framework. Furthermore, the related redundant parameters are deleted.

Authors

Institutions

Publication Details

Journal
Robotic Intelligence and Automation
Published
2024-10-11
DOI
https://doi.org/10.1108/ria-06-2023-0076
Citations
3
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A unified calibration method for robot manipulators: hand-eye parameters, kinematic parameters and TCP position calibration

Fenglei Ni, Hong Liu, Zhaoyang Chen, Kang Min
3 citations
Robotic Intelligence and Automation
Robotic Mechanisms and Dynamics
0.98
article

A unified calibration method for robot manipulators: hand-eye parameters, kinematic parameters and TCP position calibration

Fenglei Ni, Hong Liu, Zhaoyang Chen, Kang Min
article en
3 citations

Abstract

Purpose The purpose of the paper is to propose an efficient, simple and concise unified robot calibration method that simultaneously considers errors in hand-eye parameters, kinematic parameters and tool center point (TCP) position. Design/methodology/approach This paper proposes a unified robot calibration method. First, the initial hand-eye matrix and TCP position are computed without considering kinematic parameter errors. Second, the nominal TCP positions in the laser tracker coordinate system {S} are computed. The actual TCP positions in {S} are directly measured. Third, a unified parameter error calibration model is established, and the sequential quadratic programming algorithm is used for error identification. Finally, the identified errors are used for direct error compensation. Findings Simulation results prove that the proposed scheme can accurately calibrate the hand-eye parameters, kinematic parameters and TCP position simultaneously. Experimental results reveal that the maximum value of the absolute positioning errors is reduced from 5.4725 mm to 0.4095 mm (reduced by 92.52%). Thus, the proposed approach meets the accuracy requirements of most robotic applications. Originality/value The main contributions of this paper are: (1) this scheme is efficient. The method can achieve fully automatic calibration by incorporating Kronecker products for the initial hand-eye matrix and TCP position computation. Thereby significantly improving the calibration efficiency and liberating the labor force. (2) This scheme is simple and concise. The hand-eye parameters, kinematic parameters and TCP position errors are modeled in a unified framework. Furthermore, the related redundant parameters are deleted.

Robotic Intelligence and AutomationVol. 44(6)
Harbin Institute of Technology (CN)
Openalex Percentile: Top 23%
Robotic Mechanisms and Dynamics
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A unified calibration method for robot manipulators: hand-eye parameters, kinematic parameters and TCP position calibration — Fenglei Ni, Hong Liu, et al. · Robotic Intelligence and Automation (2024) | TGRS Research Map | TGRS