MTF compensation of baseline adjustable optical sparse aperture imaging system

For a single optical sparse aperture imaging system, because of the sub-mirrors’ dispersion and sparsity, the modulation transfer function (MTF) is unlikely to satisfy all frequencies due to inadequate sampling of the discrete sub-apertures. Thus, a baseline adjustable optical sparse aperture imaging system is proposed by expanding the sub-aperture array. Sufficient information from separate frequency regions can be maintained and fused. An improved Wiener filter algorithm based on the system's transfer function and noise features is designed for image restoration. Both the simulation and experiment prove that the proposed method can achieve a satisfactory MTF level and a clear reconstruction effect. The average peak signal to noise ratio is raised from 22.53 dB of degraded images to 29.17 dB of the restored images. The structural similarity index of the results is increased from 0.65 to 0.92. And compared with several conventional algorithms, scores of multiple evaluation indexes of the proposed method is the highest.

Authors

Institutions

Publication Details

Published
2024-10-11
DOI
https://doi.org/10.1117/12.3032210
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MTF compensation of baseline adjustable optical sparse aperture imaging system

Yong Wu, Liquan Dong, Tianbao Tao, Lingqin Kong et al.
Optical Systems and Laser Technology
article

MTF compensation of baseline adjustable optical sparse aperture imaging system

Yong Wu, Liquan Dong, Tianbao Tao, Lingqin Kong, Yuejin Zhao, Ming Liu, Mei Hui
article en

Abstract

For a single optical sparse aperture imaging system, because of the sub-mirrors’ dispersion and sparsity, the modulation transfer function (MTF) is unlikely to satisfy all frequencies due to inadequate sampling of the discrete sub-apertures. Thus, a baseline adjustable optical sparse aperture imaging system is proposed by expanding the sub-aperture array. Sufficient information from separate frequency regions can be maintained and fused. An improved Wiener filter algorithm based on the system's transfer function and noise features is designed for image restoration. Both the simulation and experiment prove that the proposed method can achieve a satisfactory MTF level and a clear reconstruction effect. The average peak signal to noise ratio is raised from 22.53 dB of degraded images to 29.17 dB of the restored images. The structural similarity index of the results is increased from 0.65 to 0.92. And compared with several conventional algorithms, scores of multiple evaluation indexes of the proposed method is the highest.

Beijing Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 85%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MTF compensation of baseline adjustable optical sparse aperture imaging system — Yong Wu, Liquan Dong, et al. · (2024) | TGRS Research Map | TGRS