Analysis and investigation of photon coordinate system transformation invariants in backscattering Mueller matrix computational polarimetry

Polarization imaging and computational polarimetric methods based on backscattering Mueller matrix measurement have shown great potential as a powerful information probing tool in the field of in vivo biomedical detection. However, for the backscattering polarization measurement system, the calculation and analysis of the Mueller matrix derived parameters are often related to the photon coordinate system, which can produce distinct responses with different selection and transformation of coordinate. Here, for the backscattering polarization measurement system with nearly the normal incidence, we first explore the representation of Mueller matrix elements in right-handed-nonunitary and non-right-handed-unitary systems, and further deduce and prove the photon coordinate system transformation invariants in the Mueller matrix decoding methods prevalently used in backscattering tissue polarimetry. Finally, we validate the theoretical derivation results experimentally, which can be helpful for providing a crucial criterion of parameters selection for backscattering Mueller matrix imaging under different photon coordinate systems.

Authors

Institutions

Publication Details

Published
2024-10-11
DOI
https://doi.org/10.1117/12.3032326
Citations
1
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and investigation of photon coordinate system transformation invariants in backscattering Mueller matrix computational polarimetry

Honghui He, Rui Hao, Hui Ma
1 citations
Optical Polarization and Ellipsometry
0.18
article

Analysis and investigation of photon coordinate system transformation invariants in backscattering Mueller matrix computational polarimetry

Honghui He, Rui Hao, Hui Ma
article en
1 citations

Abstract

Polarization imaging and computational polarimetric methods based on backscattering Mueller matrix measurement have shown great potential as a powerful information probing tool in the field of in vivo biomedical detection. However, for the backscattering polarization measurement system, the calculation and analysis of the Mueller matrix derived parameters are often related to the photon coordinate system, which can produce distinct responses with different selection and transformation of coordinate. Here, for the backscattering polarization measurement system with nearly the normal incidence, we first explore the representation of Mueller matrix elements in right-handed-nonunitary and non-right-handed-unitary systems, and further deduce and prove the photon coordinate system transformation invariants in the Mueller matrix decoding methods prevalently used in backscattering tissue polarimetry. Finally, we validate the theoretical derivation results experimentally, which can be helpful for providing a crucial criterion of parameters selection for backscattering Mueller matrix imaging under different photon coordinate systems.

Tsinghua University (CN)
Openalex Percentile: Top 52%
Optical Polarization and Ellipsometry
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.