Comparison of Wideband Loss Separation Technology Considering the Impact of Skin Effect
In this paper, the classical Bertotti Loss Separation Model, the complex permeability model, and a time domain One-dimensional Finite Element Method (1-D FEM) are compared for calculation of wideband losses in electrical steel sheets. In 1-D FEM, the effect of the excess loss field is investigated. Furthermore, the coupling mechanism of hysteresis loss, classical loss, and excess loss is comprehensively examined under high-frequency and high magnetic flux density conditions. The obtained results indicate that the excess loss field should be coupled in analyzing the 1-D silicon steel sheet model, and the skin effect has an impact on identifying the value of statistical parameters VSUB0/SUB.
Authors
- Long Chen (ORCID: https://orcid.org/0000-0002-3272-8667)
- Biao Huang (ORCID: https://orcid.org/0000-0001-9082-2216)
- Zheyu Zhang (ORCID: https://orcid.org/0000-0003-0768-2713)
- Xin Wen (ORCID: https://orcid.org/0000-0002-2286-2272)
- Bo Yin (ORCID: https://orcid.org/0000-0003-2139-9519)
- Tong Ben
Publication Details
- Journal
- Journal of Magnetics
- Published
- 2024-09-30
- DOI
- https://doi.org/10.4283/jmag.2024.29.3.276
- Primary Topic
- Telecommunications and Broadcasting Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00