Design and Simulation of a Microcantilever Sensor for Precise Detection of Volatile Organic Compounds

This study presents the coating of a thin film of conducting polymer on a silicon cantilever sensor. The mechanical changes in the coated microcantilever, a bimaterial, were investigated when various volatile substances, such as methanol, ethanol, acetone, propanol, dichloroethane, and toluene were added. The results showed that the coated microcantilever is much more sensitive than the uncoated one. The maximum sensitivity observed was 40.14 kHz/ppm, demonstrating a 33.8% improvement over existing systems. Findings revealed that the maximum sensitivity achieved with the proposed sensor was 83%, and the overall improvement was 6.41%. The sensors' responses were found to be reversible, sensible, fast, and proportional to the volatile concentration.

Authors

Institutions

Publication Details

Journal
Engineering Technology & Applied Science Research
Published
2024-10-09
DOI
https://doi.org/10.48084/etasr.7966
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Simulation of a Microcantilever Sensor for Precise Detection of Volatile Organic Compounds

Hareesh Pancheti, Pattan Shanmugaraja, Tejomurthy Peddiboina Hanuman Srinivas
Engineering Technology & Applied Science Research
Mechanical and Optical Resonators
article

Design and Simulation of a Microcantilever Sensor for Precise Detection of Volatile Organic Compounds

Hareesh Pancheti, Pattan Shanmugaraja, Tejomurthy Peddiboina Hanuman Srinivas
article en

Abstract

This study presents the coating of a thin film of conducting polymer on a silicon cantilever sensor. The mechanical changes in the coated microcantilever, a bimaterial, were investigated when various volatile substances, such as methanol, ethanol, acetone, propanol, dichloroethane, and toluene were added. The results showed that the coated microcantilever is much more sensitive than the uncoated one. The maximum sensitivity observed was 40.14 kHz/ppm, demonstrating a 33.8% improvement over existing systems. Findings revealed that the maximum sensitivity achieved with the proposed sensor was 83%, and the overall improvement was 6.41%. The sensors' responses were found to be reversible, sensible, fast, and proportional to the volatile concentration.

Engineering Technology & Applied Science ResearchVol. 14(5)
Annamalai University (IN)
Openalex Percentile: Top 84%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.