Novel electrochemical sensor based on poly([Cu(H2O)2P2]I2)/GCE for the determination of trimethoprim in clinical samples and cow's milk samples

A Novel bioanalytical detector based on Poly(Diaquabis(1,10-phenanthroline copper (II) Iodide) (poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE) has been fabricated by potentiodynamic polymerization of [Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>. The synthesized complex and the fabricated electrodes showed a promising electrocatalytic behavior towards the electrooxidation of Trimethoprim (TPM). Based on the regression coefficient value of scan rate with peak current and square root of peak current, the oxidation of TMP at poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE was dominated by diffusion. Under the optimized experimental conditions and square wave voltammetric parameters, the poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE revealed very wide responses in the range of concentration of 500 nM-160 μM with a limit of detection of 3.91 nM and a Limit of quantification of 13.02 nM with the relative standard deviation below 1.75 %. The valuable applicability of the fabricated sensor for the determination of TMP in real samples, including cow's milk, blood serum, and human urine, was successfully investigated. The electroanalysis results from the spike recovery and interference study provided an excellent range of recovery with an error percent of below 3.0 % in the combination effect with the potential interferents. The sensor exhibited excellent reproducibility, sensitivity, long-term stability, high accuracy, and fast response. The developed bioanalytical sensor revealed the best application prospect for biomedicine and environmental monitoring activities.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-10-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e38794
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel electrochemical sensor based on poly([Cu(H2O)2P2]I2)/GCE for the determination of trimethoprim in clinical samples and cow's milk samples

Melaku Metto, Atakilt Abebe, Minaleshewa Atlabachew, Alemu Tesfaye
1 citations
Heliyon
Electrochemical sensors and biosensors
0.21
article

Novel electrochemical sensor based on poly([Cu(H2O)2P2]I2)/GCE for the determination of trimethoprim in clinical samples and cow's milk samples

Melaku Metto, Atakilt Abebe, Minaleshewa Atlabachew, Alemu Tesfaye
article en
1 citations

Abstract

A Novel bioanalytical detector based on Poly(Diaquabis(1,10-phenanthroline copper (II) Iodide) (poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE) has been fabricated by potentiodynamic polymerization of [Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>. The synthesized complex and the fabricated electrodes showed a promising electrocatalytic behavior towards the electrooxidation of Trimethoprim (TPM). Based on the regression coefficient value of scan rate with peak current and square root of peak current, the oxidation of TMP at poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE was dominated by diffusion. Under the optimized experimental conditions and square wave voltammetric parameters, the poly([Cu(H<sub>2</sub>O)<sub>2</sub>P<sub>2</sub>]I<sub>2</sub>)/GCE revealed very wide responses in the range of concentration of 500 nM-160 μM with a limit of detection of 3.91 nM and a Limit of quantification of 13.02 nM with the relative standard deviation below 1.75 %. The valuable applicability of the fabricated sensor for the determination of TMP in real samples, including cow's milk, blood serum, and human urine, was successfully investigated. The electroanalysis results from the spike recovery and interference study provided an excellent range of recovery with an error percent of below 3.0 % in the combination effect with the potential interferents. The sensor exhibited excellent reproducibility, sensitivity, long-term stability, high accuracy, and fast response. The developed bioanalytical sensor revealed the best application prospect for biomedicine and environmental monitoring activities.

HeliyonVol. 10(20)
Jigjiga University (ET), Debark University (ET), Injibara University (ET), Bahir Dar University (ET)
Styrelsen för Internationellt Utvecklingssamarbete, Bahir Dar University, Uppsala Universitet
Zero hunger
Openalex Percentile: Top 47%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.