Using the Acoustic Velocity Vector to Assess the Condition of Buried Water Pipes
Traditionally, acoustic methods for leak inspection are based on the measurement of the acceleration of the external pipe wall or of the acoustic pressure in the pipe. This work presents an alternative inspection methodology based on measuring the acoustic velocity vector in the fluid filling the pipe. Unlike the acoustic pressure, the acoustic quantity is very sensitive to the presence of a pipe wall defect. Such defects are important to detect before they develop into leaks, which can lead to the loss of water, environmental pollution and service disruption. A new sensor design is proposed to measure the acoustic velocity vector in a pipe. A model is presented to demonstrate the underpinning theory behind this new sensor technology. The results of this model are compared with experimental data based on measurements of the acoustic velocity in an exhumed section of ductile iron pipe. These sensors can be deployed on robots to autonomously monitor the deterioration of buried pipes to support proactive asset management at a low operational cost.
Authors
- Joanna Watts (ORCID: https://orcid.org/0000-0002-0411-8976)
- Michael-David Johnson
- Kirill V. Horoshenkov (ORCID: https://orcid.org/0000-0002-6188-0369)
Institutions
- University of Sheffield (GB)
Publication Details
- Published
- 2024-10-09
- DOI
- https://doi.org/10.3390/engproc2024069187
- Primary Topic
- Water Systems and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Engineering and Physical Sciences Research Council