Beta Depth Dose Curves at STUK and PTB: measurements and simulations

Abstract Depth dose curves from beta radiation sources ( 90 Sr/ 90 Y, 85 Kr and 147 Pm) of STUK and PTB (BSS2) were measured and compared to each other. Significant differences are obvious for 90 Sr/ 90 Y and imply different conversion coefficients from the basic quantity absorbed dose rate to tissue at 0.07 mm tissue depth, Ḋ t (0.07), to the operational quantities Ḣ p (0.07) and Ḣ p (3) for normal (0 ∘ ) and oblique (45 ∘ and 60 ∘ ) radiation incidence. The resulting STUK specific conversion coefficients were used to update STUK's measurement results in a recent international comparison measurement (EURAMET 1398) — which now agree significantly better with the corresponding reference values of the comparison. For 85 Kr and 147 Pm no differences at all between STUK's and PTB's sources were observed. Finally, accompanying radiation transport simulations were undertaken to investigate the difference between STUK's and PTB's 90 Sr/ 90 Y beta radiation sources — which could be reproduced by the simulations.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-10-01
DOI
https://doi.org/10.1088/1748-0221/19/10/p10012
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beta Depth Dose Curves at STUK and PTB: measurements and simulations

J. Huikari, R. Behrens
Journal of Instrumentation
Advanced Radiotherapy Techniques
article

Beta Depth Dose Curves at STUK and PTB: measurements and simulations

J. Huikari, R. Behrens
article en

Abstract

Abstract Depth dose curves from beta radiation sources ( 90 Sr/ 90 Y, 85 Kr and 147 Pm) of STUK and PTB (BSS2) were measured and compared to each other. Significant differences are obvious for 90 Sr/ 90 Y and imply different conversion coefficients from the basic quantity absorbed dose rate to tissue at 0.07 mm tissue depth, Ḋ t (0.07), to the operational quantities Ḣ p (0.07) and Ḣ p (3) for normal (0 ∘ ) and oblique (45 ∘ and 60 ∘ ) radiation incidence. The resulting STUK specific conversion coefficients were used to update STUK's measurement results in a recent international comparison measurement (EURAMET 1398) — which now agree significantly better with the corresponding reference values of the comparison. For 85 Kr and 147 Pm no differences at all between STUK's and PTB's sources were observed. Finally, accompanying radiation transport simulations were undertaken to investigate the difference between STUK's and PTB's 90 Sr/ 90 Y beta radiation sources — which could be reproduced by the simulations.

Journal of InstrumentationVol. 19(10)
Physikalisch-Technische Bundesanstalt (DE), Radiation and Nuclear Safety Authority (FI)
Openalex Percentile: Top 75%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beta Depth Dose Curves at STUK and PTB: measurements and simulations — J. Huikari, R. Behrens · Journal of Instrumentation (2024) | TGRS Research Map | TGRS