Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range

In this paper, we study the effect of decreasing aperture diameter on signal transmission from the scintillator to the PMT. The apertures have been inserted directly between the scintillator and the photomultiplier. Three different aperture diameters have been used over a wide energy range. A newly developed fast digital spectrometer has been utilized for experimental measurement in the radial channel of the VR-1 research reactor. The detector signals with and without inserted apertures have been measured and evaluated. The aim of our research was to determine the effect of the apertures on the spectral quality, energy range and the evaluated physical quantities.

Authors

Institutions

Publication Details

Journal
European Journal of Applied Physics
Published
2024-10-02
DOI
https://doi.org/10.24018/ejphysics.2024.6.5.344
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range

Evžen Losa, Aleš Jančář, Filip Mravec, Zdeněk Matěj et al.
European Journal of Applied Physics
Radiation Detection and Scintillator Technologies
article

Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range

Evžen Losa, Aleš Jančář, Filip Mravec, Zdeněk Matěj, Jan Král, Zdeněk Kopecký, Tomáš Czakoj, Břetislav Mikel, Michal Košťál, Michal Jelínek
article en

Abstract

In this paper, we study the effect of decreasing aperture diameter on signal transmission from the scintillator to the PMT. The apertures have been inserted directly between the scintillator and the photomultiplier. Three different aperture diameters have been used over a wide energy range. A newly developed fast digital spectrometer has been utilized for experimental measurement in the radial channel of the VR-1 research reactor. The detector signals with and without inserted apertures have been measured and evaluated. The aim of our research was to determine the effect of the apertures on the spectral quality, energy range and the evaluated physical quantities.

European Journal of Applied PhysicsVol. 6(5)
Masaryk University (CZ), Czech Academy of Sciences, Institute of Scientific Instruments (CZ), Research Centre Rez (CZ), Czech Technical University in Prague (CZ)
Affordable and clean energy
Openalex Percentile: Top 75%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range — Evžen Losa, Aleš Jančář, et al. · European Journal of Applied Physics (2024) | TGRS Research Map | TGRS