Isobaric Specific Heat Capacity Measurement in the Trans-Critical Temperature Regions for Kerosene RP-3 under Pressures of 6–8 MPa

A new experimental method was proposed: the enthalpy difference method to measure the isobaric specific heat capacity of RP-3 at 6–8 MPa, 338.1–788.3 K. According to the calculation of the uncertainty of the relevant experimental apparatus, compared with the normal measurement method, the enthalpy difference method can reduce the uncertainty from 5.17 to 3.65%. The results were verified by using n-decane. The results showed that compared with National Institute of Standards and Technology (NIST), the average error of the experimental results of n-decane was 1.8%. Experimental results show that the measured peak isobaric specific heat capacity of RP-3 in this range is 3.93 kJ/kg (slightly less than the true value of the substance). As the pressure increases, its peak value gradually decreases until it becomes flat.

Authors

Institutions

Publication Details

Journal
Journal of Chemical & Engineering Data
Published
2024-10-10
DOI
https://doi.org/10.1021/acs.jced.4c00181
Citations
5
Primary Topic
Heat transfer and supercritical fluids
Type
article
Field-Weighted Citation Impact
1.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isobaric Specific Heat Capacity Measurement in the Trans-Critical Temperature Regions for Kerosene RP-3 under Pressures of 6–8 MPa

Yinlong Liu, Yanchen Fu, Xiaojia Gang, Guoqiang Xu et al.
5 citations
Journal of Chemical & Engineering Data
Heat transfer and supercritical fluids
1.87
article

Isobaric Specific Heat Capacity Measurement in the Trans-Critical Temperature Regions for Kerosene RP-3 under Pressures of 6–8 MPa

Yinlong Liu, Yanchen Fu, Xiaojia Gang, Guoqiang Xu, Haoxing Zhi
article en
5 citations

Abstract

A new experimental method was proposed: the enthalpy difference method to measure the isobaric specific heat capacity of RP-3 at 6–8 MPa, 338.1–788.3 K. According to the calculation of the uncertainty of the relevant experimental apparatus, compared with the normal measurement method, the enthalpy difference method can reduce the uncertainty from 5.17 to 3.65%. The results were verified by using n-decane. The results showed that compared with National Institute of Standards and Technology (NIST), the average error of the experimental results of n-decane was 1.8%. Experimental results show that the measured peak isobaric specific heat capacity of RP-3 in this range is 3.93 kJ/kg (slightly less than the true value of the substance). As the pressure increases, its peak value gradually decreases until it becomes flat.

Journal of Chemical & Engineering DataVol. 69(11)
Beihang University (CN)
Affordable and clean energy
Openalex Percentile: Top 16%
Heat transfer and supercritical fluids
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.