Isobaric Specific Heat Capacity Measurement in the Trans-Critical Temperature Regions for Kerosene RP-3 under Pressures of 6–8 MPa
A new experimental method was proposed: the enthalpy difference method to measure the isobaric specific heat capacity of RP-3 at 6–8 MPa, 338.1–788.3 K. According to the calculation of the uncertainty of the relevant experimental apparatus, compared with the normal measurement method, the enthalpy difference method can reduce the uncertainty from 5.17 to 3.65%. The results were verified by using n-decane. The results showed that compared with National Institute of Standards and Technology (NIST), the average error of the experimental results of n-decane was 1.8%. Experimental results show that the measured peak isobaric specific heat capacity of RP-3 in this range is 3.93 kJ/kg (slightly less than the true value of the substance). As the pressure increases, its peak value gradually decreases until it becomes flat.
Authors
- Yinlong Liu (ORCID: https://orcid.org/0000-0002-6468-8233)
- Yanchen Fu (ORCID: https://orcid.org/0000-0002-8145-7015)
- Xiaojia Gang
- Guoqiang Xu (ORCID: https://orcid.org/0000-0002-9814-3303)
- Haoxing Zhi
Institutions
- Beihang University (CN)
Publication Details
- Journal
- Journal of Chemical & Engineering Data
- Published
- 2024-10-10
- DOI
- https://doi.org/10.1021/acs.jced.4c00181
- Citations
- 5
- Primary Topic
- Heat transfer and supercritical fluids
- Type
- article
- Field-Weighted Citation Impact
- 1.87