Metrology-grade spectroscopy source based on an optical parametric oscillator

Continuous-wave optical parametric oscillators (OPOs) are widely tunable and powerful sources of narrow-linewidth radiation. These properties make them suitable for a wide range of spectroscopic studies - but so far not at the metrological level. Indeed, although important technical OPO developments occurred more than two decades ago, and commercial devices have been available for nearly as long, the long-hoped-for the potential of these devices, providing simultaneously ultralow linewidth, ultrahigh frequency stability, ultrahigh frequency accuracy, and wide wavelength coverage has not yet become a reality. Here, we present an OPO metrology system suitable for optical spectroscopy with ultra-high resolution and accuracy in the 2.2 - 3.9 μ m range. The system relies on the second-harmonic generation of the idler wave to bridge the gap to the near-infrared regime where frequency combs are readily available. By actively controlling the pump laser frequency, the idler radiation is phase-locked to an optically stabilized frequency comb, enabling a full transfer of the frequency comb’s spectral properties to the idler radiation and measuring the idler frequency with ultra-high precision. We reach fractional line widths and Allan deviations of the idler radiation at the level of 4 × 10 −14 and 1 × 10 −14 , respectively. We also perform a thorough characterization of the stabilized OPO via a comparison with a second, independent optically stabilized frequency comb and thereby determine an overall idler frequency systematic uncertainty of less than 1.2 × 10 −14 . Sources of residual frequency noise are identified. The system delivered excellent results in high-accuracy spectroscopy.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-10-10
DOI
https://doi.org/10.1364/oe.538442
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metrology-grade spectroscopy source based on an optical parametric oscillator

M. R. Schenkel, S. Schiller, Victor Vogt
3 citations
Optics Express
Analytical Chemistry and Sensors
0.87
article

Metrology-grade spectroscopy source based on an optical parametric oscillator

M. R. Schenkel, S. Schiller, Victor Vogt
article en
3 citations

Abstract

Continuous-wave optical parametric oscillators (OPOs) are widely tunable and powerful sources of narrow-linewidth radiation. These properties make them suitable for a wide range of spectroscopic studies - but so far not at the metrological level. Indeed, although important technical OPO developments occurred more than two decades ago, and commercial devices have been available for nearly as long, the long-hoped-for the potential of these devices, providing simultaneously ultralow linewidth, ultrahigh frequency stability, ultrahigh frequency accuracy, and wide wavelength coverage has not yet become a reality. Here, we present an OPO metrology system suitable for optical spectroscopy with ultra-high resolution and accuracy in the 2.2 - 3.9 μ m range. The system relies on the second-harmonic generation of the idler wave to bridge the gap to the near-infrared regime where frequency combs are readily available. By actively controlling the pump laser frequency, the idler radiation is phase-locked to an optically stabilized frequency comb, enabling a full transfer of the frequency comb’s spectral properties to the idler radiation and measuring the idler frequency with ultra-high precision. We reach fractional line widths and Allan deviations of the idler radiation at the level of 4 × 10 −14 and 1 × 10 −14 , respectively. We also perform a thorough characterization of the stabilized OPO via a comparison with a second, independent optically stabilized frequency comb and thereby determine an overall idler frequency systematic uncertainty of less than 1.2 × 10 −14 . Sources of residual frequency noise are identified. The system delivered excellent results in high-accuracy spectroscopy.

Optics ExpressVol. 32(24)
Heinrich Heine University Düsseldorf (DE)
European Partnership on Metrology, Deutsche Forschungsgemeinschaft, Heinrich-Heine-Universität Düsseldorf, H2020 European Research Council
Openalex Percentile: Top 30%
Analytical Chemistry and Sensors
0.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.