In Vivo Validation of a Computer-Assisted Bowel Length Measurement System

(1) Background: The aim of this study was to investigate potential translational factors for optical 3D reconstruction in an in vivo setting using a newly developed computerized bowel length measurement system (BMS) as a real-time application. (2) Methods: The BMS was evaluated in an in vivo porcine experiment for the influence of light source power (Watt), laparoscope-to-bowel distance (cm), bowel rotation, image background, and surgical objects in the image. Endpoints were robustness, calculated as success rate (SR) in percent, and accuracy, defined as relative error (RE) in percent of BMS measurement result to ground truth. (3) Results: A total of 1992 bowel measurements were performed on n = 7 pigs using the BMS. Bowel measurements were robust and accurate regardless of light source power, at a laparoscope-to-bowel distance of 5 cm (SR 100%, RE 18 ± 38.5%), when the small bowel was aligned horizontally (SR 100%, RE 7.3 ± 36.2%) or in the image background (SR 100%, RE 15.2 ± 23.4%), and when no additional instruments were in the image. (4) Conclusions: Applications based on optical 3D reconstruction are feasible for intraoperative use and could enable quantitative laparoscopy.

Authors

Institutions

Publication Details

Journal
Surgical Techniques Development
Published
2024-10-10
DOI
https://doi.org/10.3390/std13040027
Citations
1
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
0.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Validation of a Computer-Assisted Bowel Length Measurement System

Stefanie Speidel, Patrick Mietkowski, Benjamin Mayer, Sebastian Bodenstedt et al.
1 citations
Surgical Techniques Development
Colorectal Cancer Surgical Treatments
0.28
article

In Vivo Validation of a Computer-Assisted Bowel Length Measurement System

Stefanie Speidel, Patrick Mietkowski, Benjamin Mayer, Sebastian Bodenstedt, Karl‐Friedrich Kowalewski, Rudolf Rempel, Lena M. Schulte, Hannes Kenngott
article en
1 citations

Abstract

(1) Background: The aim of this study was to investigate potential translational factors for optical 3D reconstruction in an in vivo setting using a newly developed computerized bowel length measurement system (BMS) as a real-time application. (2) Methods: The BMS was evaluated in an in vivo porcine experiment for the influence of light source power (Watt), laparoscope-to-bowel distance (cm), bowel rotation, image background, and surgical objects in the image. Endpoints were robustness, calculated as success rate (SR) in percent, and accuracy, defined as relative error (RE) in percent of BMS measurement result to ground truth. (3) Results: A total of 1992 bowel measurements were performed on n = 7 pigs using the BMS. Bowel measurements were robust and accurate regardless of light source power, at a laparoscope-to-bowel distance of 5 cm (SR 100%, RE 18 ± 38.5%), when the small bowel was aligned horizontally (SR 100%, RE 7.3 ± 36.2%) or in the image background (SR 100%, RE 15.2 ± 23.4%), and when no additional instruments were in the image. (4) Conclusions: Applications based on optical 3D reconstruction are feasible for intraoperative use and could enable quantitative laparoscopy.

Surgical Techniques DevelopmentVol. 13(4)
Heidelberg University (DE), University Hospital Heidelberg (DE), National Center for Tumor Diseases (DE), University Children's Hospital Tübingen (DE), University Medical Centre Mannheim (DE)
Openalex Percentile: Top 35%
Colorectal Cancer Surgical Treatments
0.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Vivo Validation of a Computer-Assisted Bowel Length Measurement System — Stefanie Speidel, Patrick Mietkowski, et al. · Surgical Techniques Development (2024) | TGRS Research Map | TGRS