High Interference-Resistant Magnetic Field Probe for Non-Invasive Current Distribution Monitoring in Press Pack IGBTs of HVDC Valves

Current imbalance in press pack insulated-gate bipolar transistor (PP IGBT) impacts the device's lifespan and high-voltage direct-current (HVDC) valves' safe operation. The external magnetic field can reveal the internal current distribution of PP IGBT, warning current imbalance. However, the compact structure and high-frequency electromagnetic environment of HVDC valves introduce significant interferences in monitoring, involving both busbar current interference, device <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference and eddy current interference from the probe. This article proposes a high interference-resistant magnetic field probe featuring a bipolar coil structure and comb structure shielding, which is decoupled from busbar current, reduces <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference and avoids additional eddy current interference. Following a detailed theoretical analysis, a series of experiments was conducted. The results demonstrate that the proposed probe is sensitive to the current distribution in PP IGBTs, with busbar interference limited to 2 mV and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference reduced to 2.9%, while eddy current interference is effectively canceled. These findings validate the feasibility of the proposed method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2024-10-10
DOI
https://doi.org/10.1109/tpel.2024.3477627
Citations
2
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Interference-Resistant Magnetic Field Probe for Non-Invasive Current Distribution Monitoring in Press Pack IGBTs of HVDC Valves

Yuanfang Lu, Lei Qi, Zhonghao Dongye, Hong Shen et al.
2 citations
IEEE Transactions on Power Electronics
Magnetic Field Sensors Techniques
0.42
article

High Interference-Resistant Magnetic Field Probe for Non-Invasive Current Distribution Monitoring in Press Pack IGBTs of HVDC Valves

Yuanfang Lu, Lei Qi, Zhonghao Dongye, Hong Shen, Xiangyu Zhang, Mingyang Li, Hui Su
article en
2 citations

Abstract

Current imbalance in press pack insulated-gate bipolar transistor (PP IGBT) impacts the device's lifespan and high-voltage direct-current (HVDC) valves' safe operation. The external magnetic field can reveal the internal current distribution of PP IGBT, warning current imbalance. However, the compact structure and high-frequency electromagnetic environment of HVDC valves introduce significant interferences in monitoring, involving both busbar current interference, device <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference and eddy current interference from the probe. This article proposes a high interference-resistant magnetic field probe featuring a bipolar coil structure and comb structure shielding, which is decoupled from busbar current, reduces <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference and avoids additional eddy current interference. Following a detailed theoretical analysis, a series of experiments was conducted. The results demonstrate that the proposed probe is sensitive to the current distribution in PP IGBTs, with busbar interference limited to 2 mV and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv/dt</i> interference reduced to 2.9%, while eddy current interference is effectively canceled. These findings validate the feasibility of the proposed method.

IEEE Transactions on Power ElectronicsVol. 40(1)
North China Electric Power University (CN), Economic Research Institute (BG), Economic Research Institute (KZ)
Openalex Percentile: Top 37%
Magnetic Field Sensors Techniques
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.