Crosstalk Reduction for Mz/Mx Magnetometer Array

Optically pumped magnetometer (OPM) array shows a promising future for magnetic source imaging (MSI) in the unshielded Earth’s environment, with applications in biomedical imaging and geophysical survey. However, for total-field OPMs in the Mz/Mx mode, radio frequency (RF) magnetic fields oscillating at different frequencies tend to cause crosstalk between adjacent sensors obviously. In this work, a scheme to reduce the RF magnetic field crosstalk between sensor units was investigated. First, the dependence of the Mz magnetometer sensitivity on the RF magnetic field and cell temperature was explored experimentally. To reduce the RF field, we optimized the cell temperature and set lower laser power. With the RF field set to 150 nT, the full-width at half-maximum (FWHM) of the absorption curve of magnetic resonance is 1.12 Hz under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10~\mu $ </tex-math></inline-formula>T, which gives a magnetic resolution of 20 pT. Moreover, three types of coils consisting of the square Helmholtz coils, the biplanar X coils, and the biplanar Z coils have been deeply explored in terms of their stray fields. Compared to the other two kinds of coils, the stray field of biplanar Z coils drops more rapidly in the XOY-plane and the XOZ-plane. Specifically, the minimum spacing between adjacent sensors can be reduced from 23.87 to 10.10 cm if the RF magnetic field is generated by biplanar Z coils instead of the square Helmholtz coils, with crosstalk remaining below 0.1%.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-10
DOI
https://doi.org/10.1109/jsen.2024.3474214
Citations
3
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crosstalk Reduction for Mz/Mx Magnetometer Array

Tiedong Xu, Xiangyan Kong, Yafen Cai, Deng Pan et al.
3 citations
IEEE Sensors Journal
Magnetic Field Sensors Techniques
0.63
article

Crosstalk Reduction for Mz/Mx Magnetometer Array

Tiedong Xu, Xiangyan Kong, Yafen Cai, Deng Pan, Hanlin Guo, Kun Yang, Shuwan Zhou
article en
3 citations

Abstract

Optically pumped magnetometer (OPM) array shows a promising future for magnetic source imaging (MSI) in the unshielded Earth’s environment, with applications in biomedical imaging and geophysical survey. However, for total-field OPMs in the Mz/Mx mode, radio frequency (RF) magnetic fields oscillating at different frequencies tend to cause crosstalk between adjacent sensors obviously. In this work, a scheme to reduce the RF magnetic field crosstalk between sensor units was investigated. First, the dependence of the Mz magnetometer sensitivity on the RF magnetic field and cell temperature was explored experimentally. To reduce the RF field, we optimized the cell temperature and set lower laser power. With the RF field set to 150 nT, the full-width at half-maximum (FWHM) of the absorption curve of magnetic resonance is 1.12 Hz under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10~\mu $ </tex-math></inline-formula>T, which gives a magnetic resolution of 20 pT. Moreover, three types of coils consisting of the square Helmholtz coils, the biplanar X coils, and the biplanar Z coils have been deeply explored in terms of their stray fields. Compared to the other two kinds of coils, the stray field of biplanar Z coils drops more rapidly in the XOY-plane and the XOZ-plane. Specifically, the minimum spacing between adjacent sensors can be reduced from 23.87 to 10.10 cm if the RF magnetic field is generated by biplanar Z coils instead of the square Helmholtz coils, with crosstalk remaining below 0.1%.

IEEE Sensors JournalVol. 24(22)
Ningbo University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 31%
Magnetic Field Sensors Techniques
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Crosstalk Reduction for Mz/Mx Magnetometer Array — Tiedong Xu, Xiangyan Kong, et al. · IEEE Sensors Journal (2024) | TGRS Research Map | TGRS