Non-negligible buoyancy effect on bubbles travelling in horizontal microchannels of comparable size at small Bond numbers

When a gas bubble is transported by a liquid flow confined within a horizontal channel of comparable size, buoyancy effects are usually assumed to be negligible if the Bond number of the flow is less than unity. However, recent experimental studies showed that buoyancy may still significantly impact the bubble dynamics even when Bo ≪ 1 , provided that the flow speed is sufficiently small, such that the viscous and inertial forces are weak. To derive a new criterion to assess the significance of buoyancy on the flow of small bubbles in horizontal microchannels, we have performed systematic numerical simulations using the free software Basilisk, covering a wide range of Bond, capillary and Reynolds numbers, Bo = 0 . 004 − 0 . 4 , Ca = 1 0 − 4 − 0 . 5 and Re = 0 − 100 , and exploring the bubble-to-channel diameter ratios d b / D = 0 . 2 − 0 . 9 . We demonstrate that the nondimensional group Bo ( d b / D ) 2 / Ca is effective in assessing the importance of buoyancy in flows with negligible inertial effects. When Bo ( d b / D ) 2 / Ca < 0 . 1 , buoyancy effects are negligible and the bubble travels along the channel axis. When Bo ( d b / D ) 2 / Ca > 10 , buoyancy effects dominate and the bubble travels in the vicinity of the upper wall. For intermediate values, bubbles take equilibrium positions between the channel centre and the wall, and the threshold Bo ( d b / D ) 2 / Ca = 1 is effective in predicting whether bubbles will travel closer to the channel centre or to the wall. The capillary number at the denominator describes the lift force generated by the deformation of the bubble due to viscous shear, which acts towards the channel centre thus opposing buoyancy. Inertial forces significantly alter the shape and equilibrium position of the bubble when the Weber number of the flow exceeds unity and Bo / We < 1 . Under the action of inertia, bubbles of size comparable to the channel diameter become elongated but remain centred. Smaller bubbles migrate towards the channel wall and do not exhibit a preferential near-wall circumferential position. • Systematic analysis of the effect of Bond, capillary and Reynolds numbers. • Bubbles of diameters from 0.2 to 0.9 times the channel diameter are studied. • Bubble deformation induces a lift force acting towards the channel centre. • The ratio of Bond and capillary numbers is effective to assess the importance of buoyancy. • Inertial forces tend to push the bubble towards the channel walls.

Authors

Institutions

Publication Details

Journal
International Journal of Multiphase Flow
Published
2024-10-10
DOI
https://doi.org/10.1016/j.ijmultiphaseflow.2024.105019
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-negligible buoyancy effect on bubbles travelling in horizontal microchannels of comparable size at small Bond numbers

Sepideh Khodaparast, Giovanni Giustini, Evgenii L. Sharaborin, Mirco Magnini et al.
1 citations
International Journal of Multiphase Flow
Heat Transfer and Boiling Studies
0.21
article

Non-negligible buoyancy effect on bubbles travelling in horizontal microchannels of comparable size at small Bond numbers

Sepideh Khodaparast, Giovanni Giustini, Evgenii L. Sharaborin, Mirco Magnini, Jakub A. Cranmer
article en
1 citations

Abstract

When a gas bubble is transported by a liquid flow confined within a horizontal channel of comparable size, buoyancy effects are usually assumed to be negligible if the Bond number of the flow is less than unity. However, recent experimental studies showed that buoyancy may still significantly impact the bubble dynamics even when Bo ≪ 1 , provided that the flow speed is sufficiently small, such that the viscous and inertial forces are weak. To derive a new criterion to assess the significance of buoyancy on the flow of small bubbles in horizontal microchannels, we have performed systematic numerical simulations using the free software Basilisk, covering a wide range of Bond, capillary and Reynolds numbers, Bo = 0 . 004 − 0 . 4 , Ca = 1 0 − 4 − 0 . 5 and Re = 0 − 100 , and exploring the bubble-to-channel diameter ratios d b / D = 0 . 2 − 0 . 9 . We demonstrate that the nondimensional group Bo ( d b / D ) 2 / Ca is effective in assessing the importance of buoyancy in flows with negligible inertial effects. When Bo ( d b / D ) 2 / Ca < 0 . 1 , buoyancy effects are negligible and the bubble travels along the channel axis. When Bo ( d b / D ) 2 / Ca > 10 , buoyancy effects dominate and the bubble travels in the vicinity of the upper wall. For intermediate values, bubbles take equilibrium positions between the channel centre and the wall, and the threshold Bo ( d b / D ) 2 / Ca = 1 is effective in predicting whether bubbles will travel closer to the channel centre or to the wall. The capillary number at the denominator describes the lift force generated by the deformation of the bubble due to viscous shear, which acts towards the channel centre thus opposing buoyancy. Inertial forces significantly alter the shape and equilibrium position of the bubble when the Weber number of the flow exceeds unity and Bo / We < 1 . Under the action of inertia, bubbles of size comparable to the channel diameter become elongated but remain centred. Smaller bubbles migrate towards the channel wall and do not exhibit a preferential near-wall circumferential position. • Systematic analysis of the effect of Bond, capillary and Reynolds numbers. • Bubbles of diameters from 0.2 to 0.9 times the channel diameter are studied. • Bubble deformation induces a lift force acting towards the channel centre. • The ratio of Bond and capillary numbers is effective to assess the importance of buoyancy. • Inertial forces tend to push the bubble towards the channel walls.

International Journal of Multiphase FlowVol. 181
Skolkovo Institute of Science and Technology (RU), University of Leeds (GB), University of Nottingham (GB), University of Manchester (GB)
University of Warwick, Engineering and Physical Sciences Research Council
Climate action
Openalex Percentile: Top 51%
Heat Transfer and Boiling Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.