Post mortem Study of Catalyst Degradations Occurring in High-Temperature Proton Exchange Membrane Fuel Cells Upon Start-Stop Operation

High-temperature proton exchange membrane fuel cells (HT-PEMFCs) could replace fossil fuel-based technologies for applications which cannot involve bulky/heavy cooling systems, such as aeronautics. However, severe materials degradations upon operation prevent performance retention for acceptable lifetimes. While others have already reported degradations in HT-PEMFC, post mortem characterizations of used HT-PEMFC membrane electrode assemblies (MEAs) remain scarce. Herein, HT-PEMFC performance degradation is studied by applying a startup/shutdown protocol to a short-stack operated at 160 °C; one MEA is characterized using complementary physicochemical/electrochemical techniques to identify/understand the degradation mechanisms and their origin. This start/stop operation mode (co-flow gas reactants) leads to substantial degradation inhomogeneity. For the anode, migration, coalescence, and detachment of Pt nanoparticles are witnessed induced by high-surface-area carbon support functionalization and corrosion. The anode electrochemical surface area (ECSA) remains constant at the inlet and increases significantly at the outlet, following inhomogeneous degradation of the cathode catalyst: the Pt z+ ions formed at high potential/oxidizing conditions concentrate towards the outlet, where they redeposit locally or at the anode, after diffusion/migration across the PBI membrane. Hence, the cathode ECSA decreases significantly at the inlet. Furthermore, intense Ni-leaching from the initial PtNi alloy catalyst is reported as a result of O 2 mass-transport and phosphoric acid dilution inhomogeneity.

Authors

Institutions

Publication Details

Journal
Journal of The Electrochemical Society
Published
2024-10-01
DOI
https://doi.org/10.1149/1945-7111/ad8599
Citations
6
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Post mortem Study of Catalyst Degradations Occurring in High-Temperature Proton Exchange Membrane Fuel Cells Upon Start-Stop Operation

Amine Jaafar, Francine Roussel-Dherbey, Marion Scohy, Laëtitia Dubau et al.
6 citations
Journal of The Electrochemical Society
Fuel Cells and Related Materials
1.25
article

Post mortem Study of Catalyst Degradations Occurring in High-Temperature Proton Exchange Membrane Fuel Cells Upon Start-Stop Operation

Amine Jaafar, Francine Roussel-Dherbey, Marion Scohy, Laëtitia Dubau, Marian Chatenet, Maël Durand, Christophe Turpin, Nicolas Sergent, Axelle Baudy, Jérémi Régnier, G. Berthomé
article en
6 citations

Abstract

High-temperature proton exchange membrane fuel cells (HT-PEMFCs) could replace fossil fuel-based technologies for applications which cannot involve bulky/heavy cooling systems, such as aeronautics. However, severe materials degradations upon operation prevent performance retention for acceptable lifetimes. While others have already reported degradations in HT-PEMFC, post mortem characterizations of used HT-PEMFC membrane electrode assemblies (MEAs) remain scarce. Herein, HT-PEMFC performance degradation is studied by applying a startup/shutdown protocol to a short-stack operated at 160 °C; one MEA is characterized using complementary physicochemical/electrochemical techniques to identify/understand the degradation mechanisms and their origin. This start/stop operation mode (co-flow gas reactants) leads to substantial degradation inhomogeneity. For the anode, migration, coalescence, and detachment of Pt nanoparticles are witnessed induced by high-surface-area carbon support functionalization and corrosion. The anode electrochemical surface area (ECSA) remains constant at the inlet and increases significantly at the outlet, following inhomogeneous degradation of the cathode catalyst: the Pt z+ ions formed at high potential/oxidizing conditions concentrate towards the outlet, where they redeposit locally or at the anode, after diffusion/migration across the PBI membrane. Hence, the cathode ECSA decreases significantly at the inlet. Furthermore, intense Ni-leaching from the initial PtNi alloy catalyst is reported as a result of O 2 mass-transport and phosphoric acid dilution inhomogeneity.

Journal of The Electrochemical SocietyVol. 171(10)
Institut polytechnique de Grenoble (FR), Centre National de la Recherche Scientifique (FR), Institut National Polytechnique de Toulouse (FR), Science et Ingénierie des Matériaux et Procédés (FR), Laboratoire Interdisciplinaire de Physique (FR), Laboratoire Plasma et Conversion d'Energie (FR), Safran Electronics (Canada) (CA), Laboratoire d’Electrochimie et de Physico-chimie des Matériaux et des Interfaces (FR), Safran (France) (FR), École Nationale Supérieure d'Électrotechnique, d'Électronique, d'Informatique, d'Hydraulique et des Télécommunications (FR), Université Grenoble Alpes (FR)
Agence Nationale de la Recherche, Association Nationale de la Recherche et de la Technologie
Openalex Percentile: Top 20%
Fuel Cells and Related Materials
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.