Abstract This paper investigates experimentally and numerically structural performance of reinforced concrete (RC) circular column under double curvature buckling moment. RC circular columns are popularity embraced in RC structures not only owing to its esthetic, attractive appearance and easy for construction, but also for its better contribution for stress resistance. However, the corner or edge columns may be exposed to edge moment (EM) transferred from beam–column joint with double curvature effect. The current investigation proposes to understand the structural exhibition of such columns subjected to double curvature buckling edge moment generated at beam–column joint considering some parameters. A total number of 11 full-scale RC circular columns were constructed, installed, and then tested up to failure studying four parameters. These parameters were: clear height-to-diameter ratio ( λ ), longitudinal and lateral steel ratios ( μ and ρ , respectively) and concrete type. The λ ratio has been introduced with: 4.89, 4.51 and 4.14. The μ ratio has been presented by: 2.2%, 2.3%, 2.6%, and 3.1%, while the ρ ratio was employed with: 0.84%, 0.93%, 1.00% and 1.18%. Three concrete types were studied; one of them was normal concrete (NC), while the other ones were high-performance concretes (HPCs) which were engineered cementitious composite (ECC) and high-strength fiber reinforced concrete (HSFRC). Experimental outcomes revealed that all studied parameters could affect and upgrade the structural performance; however, both longitudinal reinforcement and height-to-diameter ratio provided significant enhancement (about 51%–64%). Parallel to those exploited experimentally, nonlinear three-dimensional finite element models (FEMs) were installed, executed and established considering experimental outcomes producing an acceptable model with an under/over-estimation of about 4%.

Authors

Institutions

Publication Details

Journal
International Journal of Concrete Structures and Materials
Published
2024-10-10
DOI
https://doi.org/10.1186/s40069-024-00712-w
Citations
7
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior of Reinforced Concrete Circular Columns Subjected to Double Curvature Buckling Moment

Walid Mansour, Ahmed Hamoda, Mohamed Emara, Sabry Fayed
7 citations
International Journal of Concrete Structures and Materials
Structural Behavior of Reinforced Concrete
1.86
article

Behavior of Reinforced Concrete Circular Columns Subjected to Double Curvature Buckling Moment

Walid Mansour, Ahmed Hamoda, Mohamed Emara, Sabry Fayed
article en
7 citations

Abstract

Abstract This paper investigates experimentally and numerically structural performance of reinforced concrete (RC) circular column under double curvature buckling moment. RC circular columns are popularity embraced in RC structures not only owing to its esthetic, attractive appearance and easy for construction, but also for its better contribution for stress resistance. However, the corner or edge columns may be exposed to edge moment (EM) transferred from beam–column joint with double curvature effect. The current investigation proposes to understand the structural exhibition of such columns subjected to double curvature buckling edge moment generated at beam–column joint considering some parameters. A total number of 11 full-scale RC circular columns were constructed, installed, and then tested up to failure studying four parameters. These parameters were: clear height-to-diameter ratio ( λ ), longitudinal and lateral steel ratios ( μ and ρ , respectively) and concrete type. The λ ratio has been introduced with: 4.89, 4.51 and 4.14. The μ ratio has been presented by: 2.2%, 2.3%, 2.6%, and 3.1%, while the ρ ratio was employed with: 0.84%, 0.93%, 1.00% and 1.18%. Three concrete types were studied; one of them was normal concrete (NC), while the other ones were high-performance concretes (HPCs) which were engineered cementitious composite (ECC) and high-strength fiber reinforced concrete (HSFRC). Experimental outcomes revealed that all studied parameters could affect and upgrade the structural performance; however, both longitudinal reinforcement and height-to-diameter ratio provided significant enhancement (about 51%–64%). Parallel to those exploited experimentally, nonlinear three-dimensional finite element models (FEMs) were installed, executed and established considering experimental outcomes producing an acceptable model with an under/over-estimation of about 4%.

International Journal of Concrete Structures and MaterialsVol. 18(1)
Kafrelsheikh University (EG), Zagazig University (EG), Higher Institute of Engineering (EG)
Kafrelsheikh University, Science and Technology Development Fund
Sustainable cities and communities
Openalex Percentile: Top 16%
Structural Behavior of Reinforced Concrete
1.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.