Interobserver and inter-modality concordance of quiescent interval slice selective magnetic resonance angiography and CT angiography in assessment of critical lower limb ischemia

Abstract Background We evaluated the noncontrast MRA as an alternate method to CT angiography in assessment of patients with lower limb ischemia, 30 patients were included in a prospective cohort study; they underwent quiescent interval slice selective magnetic resonance angiography (QISS-MRA) and computed tomographic angiography (CTA). The assessment of images was evaluated by two independent consultants. The overall subjective image quality, interobserver and intermodality concordance were calculated. Results The median acquisition time in QISS-MRA was 20 min (range 18–30 min), The overall subjective image quality was rated similarly with QISS-MRA (3.13 [95% CI 2.84–3.42]) and CTA (3.23 [95% CI 2.94–3.52]; p = 0.08) with interobserver concordance for lesion ratings in QISS-MRA reached (κ = 0.987 (SD 0.006)), while for CTA it was (κ = 0.99 (SD 0.006)), while the intermodality concordance between QISS-MRA and CTA in lesion ratings were calculated on a per segment basis and was (κ = 0.944 (SD 0.013)) for reader 1 and (κ = 0.947 (SD 0.013)) for reader 2, with sensitivity 100% and specificity 97.6% Conclusions QISS-MRA is a reliable modality for assessment of patients with critical limb ischemia.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2024-10-10
DOI
https://doi.org/10.1186/s43055-024-01355-3
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interobserver and inter-modality concordance of quiescent interval slice selective magnetic resonance angiography and CT angiography in assessment of critical lower limb ischemia

Ali H. Elmokadem, Ahmed Abdel Khalek Abdel Razek, Dina Gamal Abdelzaher, Gehad Ahmad Saleh et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Peripheral Artery Disease Management
article

Interobserver and inter-modality concordance of quiescent interval slice selective magnetic resonance angiography and CT angiography in assessment of critical lower limb ischemia

Ali H. Elmokadem, Ahmed Abdel Khalek Abdel Razek, Dina Gamal Abdelzaher, Gehad Ahmad Saleh, Amr M. Elshafei
article en

Abstract

Abstract Background We evaluated the noncontrast MRA as an alternate method to CT angiography in assessment of patients with lower limb ischemia, 30 patients were included in a prospective cohort study; they underwent quiescent interval slice selective magnetic resonance angiography (QISS-MRA) and computed tomographic angiography (CTA). The assessment of images was evaluated by two independent consultants. The overall subjective image quality, interobserver and intermodality concordance were calculated. Results The median acquisition time in QISS-MRA was 20 min (range 18–30 min), The overall subjective image quality was rated similarly with QISS-MRA (3.13 [95% CI 2.84–3.42]) and CTA (3.23 [95% CI 2.94–3.52]; p = 0.08) with interobserver concordance for lesion ratings in QISS-MRA reached (κ = 0.987 (SD 0.006)), while for CTA it was (κ = 0.99 (SD 0.006)), while the intermodality concordance between QISS-MRA and CTA in lesion ratings were calculated on a per segment basis and was (κ = 0.944 (SD 0.013)) for reader 1 and (κ = 0.947 (SD 0.013)) for reader 2, with sensitivity 100% and specificity 97.6% Conclusions QISS-MRA is a reliable modality for assessment of patients with critical limb ischemia.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 55(1)
Mansoura University (EG)
Openalex Percentile: Top 67%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interobserver and inter-modality concordance of quiescent interval slice selective magnetic resonance angiography and CT angiography in assessment of critical lower limb ischemia — Ali H. Elmokadem, Ahmed Abdel Khalek Abdel Razek, et al. · The Egyptian Journal of Radiology and Nuclear Medicine (2024) | TGRS Research Map | TGRS