Frequency-independent dual-tuned cable traps for multi-nuclear MRI and MRS

Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) of non-proton nuclei (X-nuclei) typically require additional proton imaging for anatomical reference and B<sub>0</sub> shimming. Therefore, two RF systems exist, necessitating cable traps to block the unwanted common-mode current at both Larmor frequencies of <sup>1</sup>H and X-nuclei. This study introduces a frequency-independent dual-tuned cable trap that combines a standard solenoid cable trap with a float solenoid trap to independently tune high and low frequencies without compromising performance. The methods involved theoretical analysis, electromagnetic simulations, and bench tests. Two design approaches were evaluated: a float cable trap for <sup>1</sup>H, a non-float cable trap for X-nuclei, and vice versa. Results showed that the design with the float trap for X-nuclei and non-float for <sup>1</sup>H had superior performance, with high common-mode current suppression ability at both frequencies. Bench tests confirmed these findings, demonstrating effectiveness across various static fields and X-nuclei. The proposed frequency-independent dual-tuned cable trap provides a compact and efficient solution for multinuclear MRI and MRS, enhancing safety, image quality, and flexibility.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance
Published
2024-10-11
DOI
https://doi.org/10.1016/j.jmr.2024.107786
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency-independent dual-tuned cable traps for multi-nuclear MRI and MRS

Xinqiang Yan, Yijin Yang, Ming Lu
Journal of Magnetic Resonance
Advanced MRI Techniques and Applications
article

Frequency-independent dual-tuned cable traps for multi-nuclear MRI and MRS

Xinqiang Yan, Yijin Yang, Ming Lu
article en

Abstract

Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) of non-proton nuclei (X-nuclei) typically require additional proton imaging for anatomical reference and B<sub>0</sub> shimming. Therefore, two RF systems exist, necessitating cable traps to block the unwanted common-mode current at both Larmor frequencies of <sup>1</sup>H and X-nuclei. This study introduces a frequency-independent dual-tuned cable trap that combines a standard solenoid cable trap with a float solenoid trap to independently tune high and low frequencies without compromising performance. The methods involved theoretical analysis, electromagnetic simulations, and bench tests. Two design approaches were evaluated: a float cable trap for <sup>1</sup>H, a non-float cable trap for X-nuclei, and vice versa. Results showed that the design with the float trap for X-nuclei and non-float for <sup>1</sup>H had superior performance, with high common-mode current suppression ability at both frequencies. Bench tests confirmed these findings, demonstrating effectiveness across various static fields and X-nuclei. The proposed frequency-independent dual-tuned cable trap provides a compact and efficient solution for multinuclear MRI and MRS, enhancing safety, image quality, and flexibility.

Journal of Magnetic ResonanceVol. 368
Vanderbilt University (US), Vanderbilt University Medical Center (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Affordable and clean energy
Openalex Percentile: Top 70%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Frequency-independent dual-tuned cable traps for multi-nuclear MRI and MRS — Xinqiang Yan, Yijin Yang, et al. · Journal of Magnetic Resonance (2024) | TGRS Research Map | TGRS