For a clinical application of optical triangulation to assess respiratory rate using an RGB camera and a line laser

This paper presents a non-contact and unrestrained respiration monitoring system based on the optical triangulation technique. The proposed system consists of a red-green-blue (RGB) camera and a line laser installed to face the frontal thorax of a human body. The underlying idea of the work is that the camera and line laser are mounted in opposite directions, unlike other research. By applying the proposed image processing algorithm to the camera image, laser coordinates are extracted and converted to world coordinates using the optical triangulation method. These converted world coordinates represent the height of the thorax of a person. The respiratory rate is measured by analyzing changes of the thorax surface depth. To verify system performance, the camera and the line laser are installed on the head and foot sides of a bed, respectively, facing toward the center of the bed. Twenty healthy volunteers were enrolled and underwent measurement for 100s. Evaluation results show that the optical triangulation-based image processing method demonstrates non-inferior performance to a commercial patient monitoring system with a root-mean-squared error of 0.30rpm and a maximum error of 1rpm ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>p</mml:mi> <mml:mo>></mml:mo> <mml:mn>0.05</mml:mn></mml:mrow> </mml:math> ), which implies the proposed non-contact system can be a useful alternative to the conventional healthcare method.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2024-10-10
DOI
https://doi.org/10.1186/s12880-024-01448-5
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

For a clinical application of optical triangulation to assess respiratory rate using an RGB camera and a line laser

Yoosoo Jeong, Chanho Song, Jaebum Son, Seungmin Lee
2 citations
BMC Medical Imaging
Non-Invasive Vital Sign Monitoring
0.37
article

For a clinical application of optical triangulation to assess respiratory rate using an RGB camera and a line laser

Yoosoo Jeong, Chanho Song, Jaebum Son, Seungmin Lee
article en
2 citations

Abstract

This paper presents a non-contact and unrestrained respiration monitoring system based on the optical triangulation technique. The proposed system consists of a red-green-blue (RGB) camera and a line laser installed to face the frontal thorax of a human body. The underlying idea of the work is that the camera and line laser are mounted in opposite directions, unlike other research. By applying the proposed image processing algorithm to the camera image, laser coordinates are extracted and converted to world coordinates using the optical triangulation method. These converted world coordinates represent the height of the thorax of a person. The respiratory rate is measured by analyzing changes of the thorax surface depth. To verify system performance, the camera and the line laser are installed on the head and foot sides of a bed, respectively, facing toward the center of the bed. Twenty healthy volunteers were enrolled and underwent measurement for 100s. Evaluation results show that the optical triangulation-based image processing method demonstrates non-inferior performance to a commercial patient monitoring system with a root-mean-squared error of 0.30rpm and a maximum error of 1rpm ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>p</mml:mi> <mml:mo>></mml:mo> <mml:mn>0.05</mml:mn></mml:mrow> </mml:math> ), which implies the proposed non-contact system can be a useful alternative to the conventional healthcare method.

BMC Medical ImagingVol. 24(1)
Electronics and Telecommunications Research Institute (KR), Kyungpook National University (KR), Daegu-Gyeongbuk Medical Innovation Foundation (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea, Commercializations Promotion Agency for R and D Outcomes
Openalex Percentile: Top 43%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.