Impacts of non-uniform airflow over gas cooler on the performance of transcritical CO2 air conditioning

The air flowrate and air inlet temperature at gas cooler in transcritical CO 2 air conditioning for vehicles are easily unevenly distributed due to the influence of upstream obstacles. The unevenly distributed airflow affects heat exchange between CO 2 and air, thus influencing the cooling capacity and power consumption of the air conditioning system. This study delves into the implications of such non-uniform airflow on the operational performance of transcritical CO 2 air conditioning through simulation analysis. It elucidates the mechanisms by which the uneven distribution pattern, uneven distribution direction and non-uniformity affect the cooling capacity of transcritical CO 2 air conditioning system. Moreover, the conditions of inhomogeneous airflow for enhanced heat transfer are explored by decoupling inhomogeneous flow rate and inhomogeneous temperature. Results indicate that non-uniform airflow of air temperature distributed as TB-HT (high in top and low in bottom) and air flowrate as TB-HB (high in bottom and low in top) increases the cooling capacity of 27.7% at non-uniformity of 55%. Conversely, uneven airflow of flowrate and temperature both distributed as LR-HL (high in left and low in right) at 40% non-uniformity leads to a wastage of compressor power up to 1/2. These findings reveal the dual impacts of non-uniform airflow on the performance of transcritical CO 2 air conditioning system, which emphasizes the importance of considering these impacts when designing automotive CO 2 air conditioning systems.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-10-10
DOI
https://doi.org/10.1016/j.csite.2024.105266
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impacts of non-uniform airflow over gas cooler on the performance of transcritical CO2 air conditioning

Shurong Lei, Ziliang Zhao, Huitao Yu, Jun Zhao et al.
1 citations
Case Studies in Thermal Engineering
Refrigeration and Air Conditioning Technologies
0.21
article

Impacts of non-uniform airflow over gas cooler on the performance of transcritical CO2 air conditioning

Shurong Lei, Ziliang Zhao, Huitao Yu, Jun Zhao, Qinglin Zhu, Bin Guo, Xiaoting Zhang
article en
1 citations

Abstract

The air flowrate and air inlet temperature at gas cooler in transcritical CO 2 air conditioning for vehicles are easily unevenly distributed due to the influence of upstream obstacles. The unevenly distributed airflow affects heat exchange between CO 2 and air, thus influencing the cooling capacity and power consumption of the air conditioning system. This study delves into the implications of such non-uniform airflow on the operational performance of transcritical CO 2 air conditioning through simulation analysis. It elucidates the mechanisms by which the uneven distribution pattern, uneven distribution direction and non-uniformity affect the cooling capacity of transcritical CO 2 air conditioning system. Moreover, the conditions of inhomogeneous airflow for enhanced heat transfer are explored by decoupling inhomogeneous flow rate and inhomogeneous temperature. Results indicate that non-uniform airflow of air temperature distributed as TB-HT (high in top and low in bottom) and air flowrate as TB-HB (high in bottom and low in top) increases the cooling capacity of 27.7% at non-uniformity of 55%. Conversely, uneven airflow of flowrate and temperature both distributed as LR-HL (high in left and low in right) at 40% non-uniformity leads to a wastage of compressor power up to 1/2. These findings reveal the dual impacts of non-uniform airflow on the performance of transcritical CO 2 air conditioning system, which emphasizes the importance of considering these impacts when designing automotive CO 2 air conditioning systems.

Case Studies in Thermal EngineeringVol. 63
SAIC Motor (China) (CN), Shandong University of Science and Technology (CN)
Natural Science Foundation of Shandong Province, Key Technology Research and Development Program of Shandong, Youth Innovation Technology Project of Higher School in Shandong Province
Affordable and clean energy
Openalex Percentile: Top 51%
Refrigeration and Air Conditioning Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.