Sample Thickness and Edge Proximity Influence Spatial Behavior of Filaments and Treatment Uniformity of RF Cold Atmospheric Pressure Plasma Jet

Abstract The ability of atmospheric pressure plasma jets to treat complex non-planar surfaces is often cited as their advantage over other atmospheric plasmas. However, the effect of complex surfaces on plasma parameters and treatment efficiency has seldom been studied. Herein, we investigate the interaction of the atmospheric pressure plasma slit jet (PSJ) with block polypropylene samples of different thicknesses (5 and 30 mm) moving at two different speeds. Even though the distance between the slit outlet and the sample surface was kept constant, the treatment efficiency of PSJ ignited in the Ar and $$\hbox {Ar/O}_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mtext>Ar/O</mml:mtext> <mml:mn>2</mml:mn> </mml:msub> </mml:math> gas feeds varied with the sample thickness due to the plasma parameters such as filament count and speed being affected by the different distances of the ground (the closer the ground is, the higher the discharge electric field). On the other hand, the $$\hbox {Ar/N}_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mtext>Ar/N</mml:mtext> <mml:mn>2</mml:mn> </mml:msub> </mml:math> PSJ diffuse plasma plumes were less affected by the changes in the electric field, and the treatment efficiency was the same for both sample thicknesses. Additionally, we observed a difference in the efficiency and uniformity of the PSJ treatment of the edges and the central areas in some working conditions. The treatment efficiency near the edges depended on the duration of the filament contact, i. e. , how long the local electric field trapped the filaments. Conversely, the treatment uniformity near the edges and in the central areas was different if the number of filaments changed rapidly as the discharge moved on and off the sample (the 5 mm samples treated by easily sustained Ar PSJ).

Authors

Institutions

Publication Details

Journal
Plasma Chemistry and Plasma Processing
Published
2024-10-10
DOI
https://doi.org/10.1007/s11090-024-10517-0
Citations
2
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sample Thickness and Edge Proximity Influence Spatial Behavior of Filaments and Treatment Uniformity of RF Cold Atmospheric Pressure Plasma Jet

Lukáš Dostál, David Nečas, Lenka Zajı́čková, Miloš Klíma et al.
2 citations
Plasma Chemistry and Plasma Processing
Plasma Applications and Diagnostics
0.81
article

Sample Thickness and Edge Proximity Influence Spatial Behavior of Filaments and Treatment Uniformity of RF Cold Atmospheric Pressure Plasma Jet

Lukáš Dostál, David Nečas, Lenka Zajı́čková, Miloš Klíma, Kateřina Polášková
article en
2 citations

Abstract

Abstract The ability of atmospheric pressure plasma jets to treat complex non-planar surfaces is often cited as their advantage over other atmospheric plasmas. However, the effect of complex surfaces on plasma parameters and treatment efficiency has seldom been studied. Herein, we investigate the interaction of the atmospheric pressure plasma slit jet (PSJ) with block polypropylene samples of different thicknesses (5 and 30 mm) moving at two different speeds. Even though the distance between the slit outlet and the sample surface was kept constant, the treatment efficiency of PSJ ignited in the Ar and $$\hbox {Ar/O}_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mtext>Ar/O</mml:mtext> <mml:mn>2</mml:mn> </mml:msub> </mml:math> gas feeds varied with the sample thickness due to the plasma parameters such as filament count and speed being affected by the different distances of the ground (the closer the ground is, the higher the discharge electric field). On the other hand, the $$\hbox {Ar/N}_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mtext>Ar/N</mml:mtext> <mml:mn>2</mml:mn> </mml:msub> </mml:math> PSJ diffuse plasma plumes were less affected by the changes in the electric field, and the treatment efficiency was the same for both sample thicknesses. Additionally, we observed a difference in the efficiency and uniformity of the PSJ treatment of the edges and the central areas in some working conditions. The treatment efficiency near the edges depended on the duration of the filament contact, i. e. , how long the local electric field trapped the filaments. Conversely, the treatment uniformity near the edges and in the central areas was different if the number of filaments changed rapidly as the discharge moved on and off the sample (the 5 mm samples treated by easily sustained Ar PSJ).

Plasma Chemistry and Plasma ProcessingVol. 45(1)
Central European Institute of Technology (CZ), Masaryk University (CZ), Brno University of Technology (CZ)
Ministerstvo Školství, Mládeže a Tělovýchovy, Grantová Agentura České Republiky
Clean water and sanitation
Openalex Percentile: Top 25%
Plasma Applications and Diagnostics
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.