Fundamental limits of light-wave sensing for non-contact respiration monitoring

An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing-an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away. We propose a novel scattering model, from which we derive the performance limits of the light-wave sensing system in terms of a theoretical range resolution limited by the dynamic range of the system. Using a robotic breathing phantom, we experimentally assess, for the first time, the range resolution of the testbed system and compare this to theoretical predictions. This work also introduces a process for generating stochastic respiration patterns, which may prove broadly useful to the designers of breathing phantoms. Holistically exploring practical challenges and analytical models, this paper serves as a unique and comprehensive tutorial for understanding and designing light-wave sensing systems.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-10-10
DOI
https://doi.org/10.1364/boe.514776
Primary Topic
Bluetooth and Wireless Communication Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fundamental limits of light-wave sensing for non-contact respiration monitoring

Md Zobaer Islam, Sabit Ekin, Carly Gotcher, Tyler Martinez et al.
Biomedical Optics Express
Bluetooth and Wireless Communication Technologies
article

Fundamental limits of light-wave sensing for non-contact respiration monitoring

Md Zobaer Islam, Sabit Ekin, Carly Gotcher, Tyler Martinez, John F. O’Hara, Brenden Martin
article en

Abstract

An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing-an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away. We propose a novel scattering model, from which we derive the performance limits of the light-wave sensing system in terms of a theoretical range resolution limited by the dynamic range of the system. Using a robotic breathing phantom, we experimentally assess, for the first time, the range resolution of the testbed system and compare this to theoretical predictions. This work also introduces a process for generating stochastic respiration patterns, which may prove broadly useful to the designers of breathing phantoms. Holistically exploring practical challenges and analytical models, this paper serves as a unique and comprehensive tutorial for understanding and designing light-wave sensing systems.

Biomedical Optics ExpressVol. 15(11)
Oklahoma State University (US), Texas A&M University (US)
National Science Foundation
Openalex Percentile: Top 80%
Bluetooth and Wireless Communication Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fundamental limits of light-wave sensing for non-contact respiration monitoring — Md Zobaer Islam, Sabit Ekin, et al. · Biomedical Optics Express (2024) | TGRS Research Map | TGRS