Non-enzymatic cholesterol biosensor: Electrochemical sensing based on peptide-polylactic acid thin film

Cholesterol is a fundamental lipid prevalent in eukaryotic cell membranes and circulating in the bloodstream bound to lipoproteins. It serves as a precursor to steroid hormones and is regarded as a biomarker for cardiovascular disease and other metabolic disorders. Numerous cholesterol detection methods predominantly rely on enzymes, which suffer from instability, leading to non-cost-effective biosensors with low sensitivity and poor reusability. Therefore, monitoring cholesterol levels with a feasible, rapid, and stable biosensor is critical for diagnosing and treating various disorders. This study aimed to develop a non-enzymatic cholesterol biosensor based on a selected cholesterol recognition peptide as the detection element. Screen-printed carbon electrodes (SPEs) modified with biocompatible poly-L-lactic acid (PLLA) porous nanomembranes (NMs) were utilized as support for the covalent immobilization of the peptide. Data obtained from electrochemical impedance spectroscopy (EIS) demonstrated the peptide's effective binding affinity towards cholesterol, paving the way for its implementation. The determination of cholesterol with the proposed biosensor exhibited a low limit of detection of 6.31 μM with linear responses ranging from 2-15 μM and 20-40 μM. These findings present an alternative method for cholesterol sensing by integrating novel peptides as biorecognition motifs with biocompatible polymeric materials, potentially useful as biocompatible and future point-of-care sensors.

Authors

Institutions

Publication Details

Journal
International Journal of Biological Macromolecules
Published
2024-10-09
DOI
https://doi.org/10.1016/j.ijbiomac.2024.136337
Citations
10
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-enzymatic cholesterol biosensor: Electrochemical sensing based on peptide-polylactic acid thin film

Enrico Dainese, Francesc Estrany, Elaine Armelín, Clotilde B. Angelucci et al.
10 citations
International Journal of Biological Macromolecules
Electrochemical sensors and biosensors
2.09
article

Non-enzymatic cholesterol biosensor: Electrochemical sensing based on peptide-polylactic acid thin film

Enrico Dainese, Francesc Estrany, Elaine Armelín, Clotilde B. Angelucci, Juan Torras, Sergio Oddi, Ana Lia Bernardo, Alessandro Berghella, Ahammed HM Mohammed-Sadhakathullah
article en
10 citations

Abstract

Cholesterol is a fundamental lipid prevalent in eukaryotic cell membranes and circulating in the bloodstream bound to lipoproteins. It serves as a precursor to steroid hormones and is regarded as a biomarker for cardiovascular disease and other metabolic disorders. Numerous cholesterol detection methods predominantly rely on enzymes, which suffer from instability, leading to non-cost-effective biosensors with low sensitivity and poor reusability. Therefore, monitoring cholesterol levels with a feasible, rapid, and stable biosensor is critical for diagnosing and treating various disorders. This study aimed to develop a non-enzymatic cholesterol biosensor based on a selected cholesterol recognition peptide as the detection element. Screen-printed carbon electrodes (SPEs) modified with biocompatible poly-L-lactic acid (PLLA) porous nanomembranes (NMs) were utilized as support for the covalent immobilization of the peptide. Data obtained from electrochemical impedance spectroscopy (EIS) demonstrated the peptide's effective binding affinity towards cholesterol, paving the way for its implementation. The determination of cholesterol with the proposed biosensor exhibited a low limit of detection of 6.31 μM with linear responses ranging from 2-15 μM and 20-40 μM. These findings present an alternative method for cholesterol sensing by integrating novel peptides as biorecognition motifs with biocompatible polymeric materials, potentially useful as biocompatible and future point-of-care sensors.

International Journal of Biological MacromoleculesVol. 281(Pt 2)
University of Teramo (IT), European Brain Research Institute (IT), Universitat Politècnica de Catalunya (ES)
Ministerio de Ciencia, Innovación y Universidades, European Commission, Generalitat de Catalunya, Agència de Gestió d'Ajuts Universitaris i de Recerca, Horizon 2020, Agencia Estatal de Investigación, H2020 Marie Skłodowska-Curie Actions
Affordable and clean energy
Openalex Percentile: Top 12%
Electrochemical sensors and biosensors
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.