Validación de un método de cromatografía líquida (HPLC-UV/Vis) para la cuantificación de aldehídos en agua de lluvia y aire

Aldehydes are compounds in the atmosphere formed by the photochemical degradation of other organic compounds in the troposphere and can be emitted by natural or anthropogenic sources. [Objective] An analytical method was implemented to quantify aldehyde samples in matrices such as air and rainwater. [Methodology] Aldehyde sampling and analysis were conducted using method TO-11 from the United States Environmental Protection Agency (EPA). Sampling was carried out by using adsorption cartridges coated with a 2,4-DNPH solution, forming a hydrazone with the aldehydes present in the rainwater and the air, which were tested using a liquid chromatograph coupled to a UV-visible detector (HPLC-UV/Vis). To validate the analysis technique and the analytical quality of the results, the following was determined: linearity, sensitivity, quantification limits, detection limits, repeatability, reproducibility, and recovery percentage. In the case of repeatability, the comparison of the Horwitz coefficient of variation was used with the percentages of relative standard deviation (% RSD) of the samples. [Results] The detection and quantification limits obtained range between 0.18 μg/m3 and 3.20 μg/m3 for acetaldehyde and acrolein, respectively, while quantification limits are between 0.62 μg/m3 for acetaldehyde and 4.70 μg/m3 for heptanal, data that characterizes the method’s analytical quality. [Conclusions] In general, the analysis method for aldehydes showed linearity, with R2 values equal to or greater than 0.9991 for each calibration curve, and relative deviation percentage values less than 2.25 %, indicating good precision in the analysis.

Authors

Publication Details

Journal
Uniciencia
Published
2024-08-31
DOI
https://doi.org/10.15359/ru.38-1.27
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validación de un método de cromatografía líquida (HPLC-UV/Vis) para la cuantificación de aldehídos en agua de lluvia y aire

José Pablo Sibaja-Brenes, Juan Valdés González, Henry Borbón-Alpízar, Rosa Alfaro-Solís et al.
Uniciencia
Water Quality Monitoring and Analysis
article

Validación de un método de cromatografía líquida (HPLC-UV/Vis) para la cuantificación de aldehídos en agua de lluvia y aire

José Pablo Sibaja-Brenes, Juan Valdés González, Henry Borbón-Alpízar, Rosa Alfaro-Solís, Melissa Araya-Araya, José Carlos Mora-Barrantes, Roy Soto-Fallas
article en

Abstract

Aldehydes are compounds in the atmosphere formed by the photochemical degradation of other organic compounds in the troposphere and can be emitted by natural or anthropogenic sources. [Objective] An analytical method was implemented to quantify aldehyde samples in matrices such as air and rainwater. [Methodology] Aldehyde sampling and analysis were conducted using method TO-11 from the United States Environmental Protection Agency (EPA). Sampling was carried out by using adsorption cartridges coated with a 2,4-DNPH solution, forming a hydrazone with the aldehydes present in the rainwater and the air, which were tested using a liquid chromatograph coupled to a UV-visible detector (HPLC-UV/Vis). To validate the analysis technique and the analytical quality of the results, the following was determined: linearity, sensitivity, quantification limits, detection limits, repeatability, reproducibility, and recovery percentage. In the case of repeatability, the comparison of the Horwitz coefficient of variation was used with the percentages of relative standard deviation (% RSD) of the samples. [Results] The detection and quantification limits obtained range between 0.18 μg/m3 and 3.20 μg/m3 for acetaldehyde and acrolein, respectively, while quantification limits are between 0.62 μg/m3 for acetaldehyde and 4.70 μg/m3 for heptanal, data that characterizes the method’s analytical quality. [Conclusions] In general, the analysis method for aldehydes showed linearity, with R2 values equal to or greater than 0.9991 for each calibration curve, and relative deviation percentage values less than 2.25 %, indicating good precision in the analysis.

UnicienciaVol. 38(1)
Openalex Percentile: Top 79%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validación de un método de cromatografía líquida (HPLC-UV/Vis) para la cuantificación de aldehídos en agua de lluvia y aire — José Pablo Sibaja-Brenes, Juan Valdés González, et al. · Uniciencia (2024) | TGRS Research Map | TGRS