Identifying Two-Reset Conditions for Closed-Loop Sinusoidal Input Reset Control Systems

The frequency response describes the steady-state behavior of a control system to sinusoidal inputs across varying frequencies and serves as an effective tool for system design. In closed-loop reset control systems, frequency response analysis reveals two distinct scenarios: systems with two reset instants per steady-state cycle and systems with multiple (more than two) reset instants per cycle. Existing frequency response analyses often assume only two reset instants, which can result in inaccuracies for systems with multiple resets. Additionally, multiple resets can generate high-magnitude higher-order harmonics, which may result in system performance degradation. This study introduces a novel method to identify conditions where only two reset instants occur in closed-loop reset systems. This method allows designers to avoid multiple-reset actions during the system design phase. By ensuring the system operates with only two resets per cycle, this method enhances the accuracy of frequency response analyses that assume this condition. The effectiveness of the proposed method is validated through simulations and experimental tests on a precision motion system.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/mesa61532.2024.10704897
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifying Two-Reset Conditions for Closed-Loop Sinusoidal Input Reset Control Systems

S. Hassan HosseinNia, Xinxin Zhang
Real-time simulation and control systems
article

Identifying Two-Reset Conditions for Closed-Loop Sinusoidal Input Reset Control Systems

S. Hassan HosseinNia, Xinxin Zhang
article en

Abstract

The frequency response describes the steady-state behavior of a control system to sinusoidal inputs across varying frequencies and serves as an effective tool for system design. In closed-loop reset control systems, frequency response analysis reveals two distinct scenarios: systems with two reset instants per steady-state cycle and systems with multiple (more than two) reset instants per cycle. Existing frequency response analyses often assume only two reset instants, which can result in inaccuracies for systems with multiple resets. Additionally, multiple resets can generate high-magnitude higher-order harmonics, which may result in system performance degradation. This study introduces a novel method to identify conditions where only two reset instants occur in closed-loop reset systems. This method allows designers to avoid multiple-reset actions during the system design phase. By ensuring the system operates with only two resets per cycle, this method enhances the accuracy of frequency response analyses that assume this condition. The effectiveness of the proposed method is validated through simulations and experimental tests on a precision motion system.

Delft University of Technology (NL)
Affordable and clean energy
Openalex Percentile: Top 80%
Real-time simulation and control systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.