Inductive Voltage Transformer Behaviour in the Frequency Range from 9 kHz Up to 150 kHz

With the widespread diffusion of power converters able to be directly connected to Medium Voltage (MV) grids, there is the need to measure high frequency distortion, that is from 9 kHz up to 150 kHz. Inductive Voltage Transformers (VTs) are still the most installed voltage transducers in the power systems, but the knowledge of their behaviour in this frequency range is still an open issue. The aim of this paper is to analyse the behaviour of inductive VTs from 9 kHz up to 150 kHz. A commercial VT has been tested and the results show that the nonlinearity of the iron core can influence the behaviour of inductive VTs at least up to 150 kHz.

Authors

Institutions

Publication Details

Published
2024-09-18
DOI
https://doi.org/10.1109/amps62611.2024.10706667
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inductive Voltage Transformer Behaviour in the Frequency Range from 9 kHz Up to 150 kHz

Daniele Palladini, Palma Sara Letizia, Mario Luiso, Antonio Delle Femine et al.
Sensor Technology and Measurement Systems
article

Inductive Voltage Transformer Behaviour in the Frequency Range from 9 kHz Up to 150 kHz

Daniele Palladini, Palma Sara Letizia, Mario Luiso, Antonio Delle Femine, G. Crotti, Domenico Giordano, Claudio Iodice, Giovanni D’Avanzo, Carmine Landi, Daniele Gallo
article en

Abstract

With the widespread diffusion of power converters able to be directly connected to Medium Voltage (MV) grids, there is the need to measure high frequency distortion, that is from 9 kHz up to 150 kHz. Inductive Voltage Transformers (VTs) are still the most installed voltage transducers in the power systems, but the knowledge of their behaviour in this frequency range is still an open issue. The aim of this paper is to analyse the behaviour of inductive VTs from 9 kHz up to 150 kHz. A commercial VT has been tested and the results show that the nonlinearity of the iron core can influence the behaviour of inductive VTs at least up to 150 kHz.

University of Campania "Luigi Vanvitelli" (IT), Ricerca sul Sistema Energetico (Italy) (IT), Istituto Nazionale di Ricerca Metrologica (IT)
Affordable and clean energy
Openalex Percentile: Top 81%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.