PMU Implementation Using IEC61850 Sampled Values Implemented in a CPC Platform

This paper presents the implementation of Phasor Measurement Units (PMUs) using IEC61850 Sampled Values (SV) in a Centralized Protection and Control (CPC) platform called EPICS platform. The SV-PMU microservice is developed and implemented via software on an EDGE Server, and its performance is evaluated in laboratory in both steady and transient states according to IEEE/IEC 60255-118-1:2018 standard. The evaluation tests were executed using a Real-Time Digital Simulator (RTDS). Two methods for the evaluation of the behaviour of the PMUs were implemented. The first is an evaluation in real-time using a Real-Time Automation Controller (RTAC) and the second one is an evaluation in offline mode using a Python Script. Two instances of the SV-PMU microservice were evaluated, the first one uses as signal inputs the SV generated in RTDS and the second one uses the signals generated by a Stand-Alone Mergin Unit. The tests results demonstrate the microservice's compliance with the standards, highlighting its potential to enhance the EPICS platform's capabilities as a CPC system in Digital Substations and to contributes to the deployment of Wide Area Monitoring, Protection, and Control (WAMPAC) systems in the power grid. Future work includes comparing the behaviour of SV-PMU microservice with commercial PMUs to validate its real-world applicability.

Authors

Institutions

Publication Details

Published
2024-09-18
DOI
https://doi.org/10.1109/amps62611.2024.10706693
Citations
3
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PMU Implementation Using IEC61850 Sampled Values Implemented in a CPC Platform

Maria Teresa Villén Martínez, Aníbal Antonio Prada Hurtado, M. Mañana, M. A. Oliván et al.
3 citations
Smart Grid Security and Resilience
0.98
article

PMU Implementation Using IEC61850 Sampled Values Implemented in a CPC Platform

Maria Teresa Villén Martínez, Aníbal Antonio Prada Hurtado, M. Mañana, M. A. Oliván, Carlos Rodriguez del Castillo, Eduardo Martínez Carrasco
article en
3 citations

Abstract

This paper presents the implementation of Phasor Measurement Units (PMUs) using IEC61850 Sampled Values (SV) in a Centralized Protection and Control (CPC) platform called EPICS platform. The SV-PMU microservice is developed and implemented via software on an EDGE Server, and its performance is evaluated in laboratory in both steady and transient states according to IEEE/IEC 60255-118-1:2018 standard. The evaluation tests were executed using a Real-Time Digital Simulator (RTDS). Two methods for the evaluation of the behaviour of the PMUs were implemented. The first is an evaluation in real-time using a Real-Time Automation Controller (RTAC) and the second one is an evaluation in offline mode using a Python Script. Two instances of the SV-PMU microservice were evaluated, the first one uses as signal inputs the SV generated in RTDS and the second one uses the signals generated by a Stand-Alone Mergin Unit. The tests results demonstrate the microservice's compliance with the standards, highlighting its potential to enhance the EPICS platform's capabilities as a CPC system in Digital Substations and to contributes to the deployment of Wide Area Monitoring, Protection, and Control (WAMPAC) systems in the power grid. Future work includes comparing the behaviour of SV-PMU microservice with commercial PMUs to validate its real-world applicability.

Universidad de Cantabria (ES), Red Electrica de Espana (Spain) (ES), CIRCE - Centro Tecnológico (ES)
Openalex Percentile: Top 23%
Smart Grid Security and Resilience
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PMU Implementation Using IEC61850 Sampled Values Implemented in a CPC Platform — Maria Teresa Villén Martínez, Aníbal Antonio Prada Hurtado, et al. · (2024) | TGRS Research Map | TGRS