A dedicated pencil beam scan system is developed and integrated into the proton therapy (PT) system of China Institute by a joint effort of Pyramid Consult Inc. and China Institute of Atomic Energy (CIAE). In nozzle commissioning, a proton beam with an intensity of tens of nanoamperes is provided by the CIAE beam production system, including a 242-MeV superconducting cyclotron and a fast energy variable beam transportation system. Most scanning devices are commercial products from the pyramid, including the ion chambers, helium beam path, magnet, and amplifier. A scintillator camera system named Lynx from IBA provides position readouts of the beam spot during commissioning. A dedicated controlling software and related strategy for the beam commission of the scanning system is developed by the CIAE team. In the commissioning, a straightforward irradiation consisting of 114 beam spots is carried out to evaluate the scanning magnets’ nonlinearity and crosstalks. Afterward, Lynx generates these coordinates and analyzes them using the reported software. A modified 2-D polynomial fitting, including hyperbolic functions, is invested in the commissioning to yield an open-loop control accuracy in orders of millimeters. An iterative learning algorithm has also been developed to give even better accuracy. A 50-mm separation irradiation map consisting of 37 points is carried out by combining these two corrections on the first commission day, reaching an accuracy of 0.55 mm. An irradiation field of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$250\times 250$ </tex-math></inline-formula> mm is also verified at the same time. The method and the first-day result will be reported in this article.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-10-09
DOI
https://doi.org/10.1109/tns.2024.3476946
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Online Parameter Identification and Control in the Commissioning of Nozzle for CIAE Proton Therapy System

C. X. Liu, B. Zhao, Qiankun Guo, Zhiguo Yin et al.
IEEE Transactions on Nuclear Science
Radiation Therapy and Dosimetry
article

Online Parameter Identification and Control in the Commissioning of Nozzle for CIAE Proton Therapy System

C. X. Liu, B. Zhao, Qiankun Guo, Zhiguo Yin, Tianjue Zhang, Chuan Wang, Rui Xiong, Yongjun Ma
article en

Abstract

A dedicated pencil beam scan system is developed and integrated into the proton therapy (PT) system of China Institute by a joint effort of Pyramid Consult Inc. and China Institute of Atomic Energy (CIAE). In nozzle commissioning, a proton beam with an intensity of tens of nanoamperes is provided by the CIAE beam production system, including a 242-MeV superconducting cyclotron and a fast energy variable beam transportation system. Most scanning devices are commercial products from the pyramid, including the ion chambers, helium beam path, magnet, and amplifier. A scintillator camera system named Lynx from IBA provides position readouts of the beam spot during commissioning. A dedicated controlling software and related strategy for the beam commission of the scanning system is developed by the CIAE team. In the commissioning, a straightforward irradiation consisting of 114 beam spots is carried out to evaluate the scanning magnets’ nonlinearity and crosstalks. Afterward, Lynx generates these coordinates and analyzes them using the reported software. A modified 2-D polynomial fitting, including hyperbolic functions, is invested in the commissioning to yield an open-loop control accuracy in orders of millimeters. An iterative learning algorithm has also been developed to give even better accuracy. A 50-mm separation irradiation map consisting of 37 points is carried out by combining these two corrections on the first commission day, reaching an accuracy of 0.55 mm. An irradiation field of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$250\times 250$ </tex-math></inline-formula> mm is also verified at the same time. The method and the first-day result will be reported in this article.

IEEE Transactions on Nuclear ScienceVol. 72(3)
China Institute of Atomic Energy (CN)
Openalex Percentile: Top 68%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.