Low-Cost High-Performance Generator for Testing Current Transformers Based on Frequency-Domain Feedback
Characterizing the harmonic measurement performance of current transformers (CTs) requires a proper generator for applying realistic periodic current waveforms, mimicking those found in distribution grids. This paper proposes an approach for implementing a high-performance current generator, based on the usual, low-cost architecture consisting of a power amplifier, a transformer to boost its capability and a reference CT. Frequency-domain error feedback is adopted, with feedback gain set according to a preliminary frequency response measurement. This enables heavily mitigating the nonlinearity introduced by the current boost transformer, which no longer must be heavily overdesigned to reach high accuracy.
Authors
- Marco Faifer (ORCID: https://orcid.org/0000-0002-8777-5444)
- Sergio Toscani (ORCID: https://orcid.org/0000-0003-2317-5818)
- Roberto Ottoboni (ORCID: https://orcid.org/0000-0002-5371-1346)
- Christian Laurano (ORCID: https://orcid.org/0000-0002-6011-6246)
Institutions
- Politecnico di Milano (IT)
Publication Details
- Published
- 2024-09-18
- DOI
- https://doi.org/10.1109/amps62611.2024.10706679
- Citations
- 3
- Primary Topic
- Sensor Technology and Measurement Systems
- Type
- article
- Field-Weighted Citation Impact
- 1.05