Comparison of Different Obturation Techniques in the Dentinal Tubule Penetration of EndoSequence® Bioceramic Sealer HiFlow™: An In-Vitro Study

Background This study aimed to assess the dentinal tubule penetration of bioceramic sealer (DTPB) using EndoSequence® Bioceramic Sealer HiFlow™ (BCHF). Three obturation techniques were compared, namely, single cone (SC), cold lateral condensation (CLC), and warm vertical compaction (WVC) using scanning electron microscopy (SEM). Methodology A total of 45 intact mandibular premolars were decoronated, instrumented, and irrigated with uniform procedures. Subsequently, they were randomly assigned into the following three groups according to the gutta-percha and BCHF obturation technique: Group 1 (n = 15) with the SC technique, Group 2 (n = 15) with the CLC technique, and Group 3 (n = 15) with the WVC technique. Afterward, the roots were sectioned at three levels (coronal, middle, apical) from the apex and examined using SEM to determine the maximum distance of DTPB in µm. The collected data were analyzed using SPSS software (IBM Corp., Armonk, NY, USA) using the one-way analysis of variance test and Bonferroni tests. The level of significance was set at α of 0.05. Results Significant differences were observed in the maximum distances of DTPB values among the three levels across groups (p < 0.05). Both the WVC and CLC groups exhibited higher values compared to the SC group (p < 0.05). Specifically, the DTPB maximum distance at the apical third was significantly higher in the CLC group than in the WVC and SC groups (p < 0.05). Additionally, the coronal third in each group demonstrated significant DTPB maximum distance (p < 0.05) compared to the other groups. Conclusions BCHF with the WVC and CLC obturation technique showed the best performance in DTPB maximum distance values at the three levels.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-09
DOI
https://doi.org/10.7759/cureus.71155
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Different Obturation Techniques in the Dentinal Tubule Penetration of EndoSequence® Bioceramic Sealer HiFlow™: An In-Vitro Study

Helen Rushdi Ayoubi, Hassan Achour, Yasser Alsayed Tolibah, Mohammad Mobayed
Cureus
Endodontics and Root Canal Treatments
article

Comparison of Different Obturation Techniques in the Dentinal Tubule Penetration of EndoSequence® Bioceramic Sealer HiFlow™: An In-Vitro Study

Helen Rushdi Ayoubi, Hassan Achour, Yasser Alsayed Tolibah, Mohammad Mobayed
article en

Abstract

Background This study aimed to assess the dentinal tubule penetration of bioceramic sealer (DTPB) using EndoSequence® Bioceramic Sealer HiFlow™ (BCHF). Three obturation techniques were compared, namely, single cone (SC), cold lateral condensation (CLC), and warm vertical compaction (WVC) using scanning electron microscopy (SEM). Methodology A total of 45 intact mandibular premolars were decoronated, instrumented, and irrigated with uniform procedures. Subsequently, they were randomly assigned into the following three groups according to the gutta-percha and BCHF obturation technique: Group 1 (n = 15) with the SC technique, Group 2 (n = 15) with the CLC technique, and Group 3 (n = 15) with the WVC technique. Afterward, the roots were sectioned at three levels (coronal, middle, apical) from the apex and examined using SEM to determine the maximum distance of DTPB in µm. The collected data were analyzed using SPSS software (IBM Corp., Armonk, NY, USA) using the one-way analysis of variance test and Bonferroni tests. The level of significance was set at α of 0.05. Results Significant differences were observed in the maximum distances of DTPB values among the three levels across groups (p < 0.05). Both the WVC and CLC groups exhibited higher values compared to the SC group (p < 0.05). Specifically, the DTPB maximum distance at the apical third was significantly higher in the CLC group than in the WVC and SC groups (p < 0.05). Additionally, the coronal third in each group demonstrated significant DTPB maximum distance (p < 0.05) compared to the other groups. Conclusions BCHF with the WVC and CLC obturation technique showed the best performance in DTPB maximum distance values at the three levels.

CureusVol. 16(10)
Damascus University (SY)
Damascus University
Openalex Percentile: Top 75%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.