Achieving torsional stability of distal femur fractures through a single approach using 90–90 construct

Distal femoral fractures (DFFs) are frequently characterised by significant comminution, osteoporosis, high implant failure, insufficient fixation because of a shortened distal part, non-union, malunion, and poor outcome. Our report presents two cases treated with dual plating in a 90-90 construct to achieve torsional stability. DFF fixation by dual plating in a 90-90 configuration proved to be a superior fixation similar to 90-90 plating for distal humerus fracture, since 90-90 plate fixation had significantly greater torque to failure load and has more resistance to torsional loading. Two cases of distal femur non-union with implant failure were treated utilising a double plating. These non-union cases exhibited radiological healing and knee range of motion at a mean follow-up of 6 months. This technique offers a modified way of treating these difficult non-union cases through a single incision, providing mechanical stability conducive to fracture healing.

Authors

Institutions

Publication Details

Journal
BMJ Case Reports
Published
2024-10-01
DOI
https://doi.org/10.1136/bcr-2023-258919
Citations
1
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving torsional stability of distal femur fractures through a single approach using 90–90 construct

Mayank Vijayvargiya, Sanjay R Agarwala, Avinashdev Upadhyay
1 citations
BMJ Case Reports
Bone fractures and treatments
0.39
article

Achieving torsional stability of distal femur fractures through a single approach using 90–90 construct

Mayank Vijayvargiya, Sanjay R Agarwala, Avinashdev Upadhyay
article en
1 citations

Abstract

Distal femoral fractures (DFFs) are frequently characterised by significant comminution, osteoporosis, high implant failure, insufficient fixation because of a shortened distal part, non-union, malunion, and poor outcome. Our report presents two cases treated with dual plating in a 90-90 construct to achieve torsional stability. DFF fixation by dual plating in a 90-90 configuration proved to be a superior fixation similar to 90-90 plating for distal humerus fracture, since 90-90 plate fixation had significantly greater torque to failure load and has more resistance to torsional loading. Two cases of distal femur non-union with implant failure were treated utilising a double plating. These non-union cases exhibited radiological healing and knee range of motion at a mean follow-up of 6 months. This technique offers a modified way of treating these difficult non-union cases through a single incision, providing mechanical stability conducive to fracture healing.

BMJ Case ReportsVol. 17(10)
P. D. Hinduja Hospital and Medical Research Centre (IN), National Hospital (IN)
Openalex Percentile: Top 33%
Bone fractures and treatments
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.