Achieving torsional stability of distal femur fractures through a single approach using 90–90 construct
Distal femoral fractures (DFFs) are frequently characterised by significant comminution, osteoporosis, high implant failure, insufficient fixation because of a shortened distal part, non-union, malunion, and poor outcome. Our report presents two cases treated with dual plating in a 90-90 construct to achieve torsional stability. DFF fixation by dual plating in a 90-90 configuration proved to be a superior fixation similar to 90-90 plating for distal humerus fracture, since 90-90 plate fixation had significantly greater torque to failure load and has more resistance to torsional loading. Two cases of distal femur non-union with implant failure were treated utilising a double plating. These non-union cases exhibited radiological healing and knee range of motion at a mean follow-up of 6 months. This technique offers a modified way of treating these difficult non-union cases through a single incision, providing mechanical stability conducive to fracture healing.
Authors
- Mayank Vijayvargiya (ORCID: https://orcid.org/0000-0002-2405-0411)
- Sanjay R Agarwala
- Avinashdev Upadhyay
Institutions
- P. D. Hinduja Hospital and Medical Research Centre (IN)
- National Hospital (IN)
Publication Details
- Journal
- BMJ Case Reports
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1136/bcr-2023-258919
- Citations
- 1
- Primary Topic
- Bone fractures and treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.39