Measured and predicted sound transmission through a laboratory concrete floor

The direct sound transmission through a simple, massive, homogeneous building element with and without lining is investigated experimentally and compared with analytical and empirical models from the literature. A 150 mm thick concrete floor and a 100 mm thick floating floor were measured in the floor transmission facility of the National Research Council Canada, i.e. without flanking sound transmission. In addition to the sound reduction index and the normalized impact sound pressure level, loss factors, radiation efficiencies, and mean squared velocities were recorded in the laboratory. The measured data is compared to established models of sound transmission. A focus is placed on the calculation model of ISO 12354-1 (Appendix B), which uses calculated radiation efficiencies and loss factors to predict the sound reduction index of heavy, homogeneous building elements. Some difficulties with the calculation model and the examples in the standard are discussed. In principle, the results in this study show that the calculation model of ISO 12354-1 gives good estimates when the correct input parameters are used. However, deviations between the calculated and the measured loss factors and radiation efficiencies have large effects on the accuracy of the estimates, particularly in the region around the coincidence frequency.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3902
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measured and predicted sound transmission through a laboratory concrete floor

Markus Müller-Trapet, Christoph Hoeller
NOISE-CON proceedings
Acoustic Wave Phenomena Research
article

Measured and predicted sound transmission through a laboratory concrete floor

Markus Müller-Trapet, Christoph Hoeller
article en

Abstract

The direct sound transmission through a simple, massive, homogeneous building element with and without lining is investigated experimentally and compared with analytical and empirical models from the literature. A 150 mm thick concrete floor and a 100 mm thick floating floor were measured in the floor transmission facility of the National Research Council Canada, i.e. without flanking sound transmission. In addition to the sound reduction index and the normalized impact sound pressure level, loss factors, radiation efficiencies, and mean squared velocities were recorded in the laboratory. The measured data is compared to established models of sound transmission. A focus is placed on the calculation model of ISO 12354-1 (Appendix B), which uses calculated radiation efficiencies and loss factors to predict the sound reduction index of heavy, homogeneous building elements. Some difficulties with the calculation model and the examples in the standard are discussed. In principle, the results in this study show that the calculation model of ISO 12354-1 gives good estimates when the correct input parameters are used. However, deviations between the calculated and the measured loss factors and radiation efficiencies have large effects on the accuracy of the estimates, particularly in the region around the coincidence frequency.

NOISE-CON proceedingsVol. 270(4)
OTH Regensburg (DE), National Research Council Canada (CA)
Sustainable cities and communities
Openalex Percentile: Top 84%
Acoustic Wave Phenomena Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.