Consideration on the efficient calibration method for low-cost microphones

Current microphone calibration methods in the international standards are basically targeting laboratory and working standard microphones specified in the IEC 61094-2 and IEC 61094-4, respectively. These methods are promising to ensure the reliability however there are many difficulties in applying it to low-cost acoustic sensors such as MEMS microphones, which are rapidly becoming widespread, with aspects of time and cost. Moreover, since the installation conditions for these low-cost microphones are different from those of standardized measurement microphones, calibration methods that take these usage conditions into consideration are required. As potential methods to overcome the problems, the feasibility of the active coupler method applicable to surface mounted condition and the bulk calibration method in the reverberation room are investigated. Both proposed methods can be applied under actual installation conditions and enable rapid and cost-efficient calibration. In this study, methods and procedures for securing traceability are proposed, and uncertainty evaluation is conducted.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_4201
Primary Topic
Multimedia Communication and Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Consideration on the efficient calibration method for low-cost microphones

In-Jee Jung, Wan‐Ho Cho
1 links
NOISE-CON proceedings
Multimedia Communication and Technology
article

Consideration on the efficient calibration method for low-cost microphones

In-Jee Jung, Wan‐Ho Cho
article en

Abstract

Current microphone calibration methods in the international standards are basically targeting laboratory and working standard microphones specified in the IEC 61094-2 and IEC 61094-4, respectively. These methods are promising to ensure the reliability however there are many difficulties in applying it to low-cost acoustic sensors such as MEMS microphones, which are rapidly becoming widespread, with aspects of time and cost. Moreover, since the installation conditions for these low-cost microphones are different from those of standardized measurement microphones, calibration methods that take these usage conditions into consideration are required. As potential methods to overcome the problems, the feasibility of the active coupler method applicable to surface mounted condition and the bulk calibration method in the reverberation room are investigated. Both proposed methods can be applied under actual installation conditions and enable rapid and cost-efficient calibration. In this study, methods and procedures for securing traceability are proposed, and uncertainty evaluation is conducted.

NOISE-CON proceedingsVol. 270(2)
Korea Research Institute of Standards and Science (KR)
Openalex Percentile: Top 72%
Multimedia Communication and Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.