Measurement uncertainty of ISO CD 23351-2 - Preliminary results
The purpose of our study was to determine the measurement uncertainty of ISO CD 23351-2 draft standard. Two sub-studies were conducted. In study 1, an accuracy experiment was conducted where 7 participants tested in the same room (in situ) two different products (full enclosure and partial enclosure). In study 2, an experiment was conducted where a single participant tested two different products in several rooms varying in room volume and reverberation time. Study 1 yielded an in-situ reproducibility standard deviation of 0.80.9 dB. Study 2 yielded a between-site standard deviation of 0.7 dB. The small standard deviations suggest that the technical content should not be essentially changed in the next versions of the standard. The results could be considered in next version of the standard ISO DIS 23351-2.
Authors
- Riccardo Caradonna (ORCID: https://orcid.org/0000-0001-7652-2583)
- Jukka Keränen (ORCID: https://orcid.org/0000-0001-6124-9596)
- Arianna Astolfi (ORCID: https://orcid.org/0000-0003-2010-6884)
- Valtteri Hongisto (ORCID: https://orcid.org/0000-0003-2901-2702)
Institutions
- Turku University of Applied Sciences (FI)
- Politecnico di Torino (IT)
Publication Details
- Journal
- NOISE-CON proceedings
- Published
- 2024-10-04
- DOI
- https://doi.org/10.3397/in_2024_4242
- Primary Topic
- Advanced Measurement and Metrology Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00