Research on single-phase grounding detection method in small-current grounding systems based on image recognition

In small-current grounding systems, the fault current during a single-phase grounding fault is small, and the transient process is complex, leading to challenges in line selection accuracy and reliability. This paper proposes a single-phase grounding line selection method based on transfer learning using the ResNet-50 model. Zero-sequence voltage and current waveforms at the fault moment are preprocessed and combined to generate training data for the model. Simulation results using PSCAD demonstrate that the proposed method achieves 99.77% validation accuracy, even under noisy conditions. These results confirm the method’s feasibility and reliability in identifying grounding faults in various conditions.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2024-10-09
DOI
https://doi.org/10.3389/fenrg.2024.1473472
Citations
4
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on single-phase grounding detection method in small-current grounding systems based on image recognition

Xuekun Xu, Guangfen Wan
4 citations
Frontiers in Energy Research
Power Systems Fault Detection
1.31
article

Research on single-phase grounding detection method in small-current grounding systems based on image recognition

Xuekun Xu, Guangfen Wan
article en
4 citations

Abstract

In small-current grounding systems, the fault current during a single-phase grounding fault is small, and the transient process is complex, leading to challenges in line selection accuracy and reliability. This paper proposes a single-phase grounding line selection method based on transfer learning using the ResNet-50 model. Zero-sequence voltage and current waveforms at the fault moment are preprocessed and combined to generate training data for the model. Simulation results using PSCAD demonstrate that the proposed method achieves 99.77% validation accuracy, even under noisy conditions. These results confirm the method’s feasibility and reliability in identifying grounding faults in various conditions.

Frontiers in Energy ResearchVol. 12
Nanjing Tech University (CN), China National Offshore Oil Corporation (China) (CN)
Openalex Percentile: Top 19%
Power Systems Fault Detection
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.